901-10037001/1.1 FS 20/25 Operators Manual
Page 5.16 Maintenance and Troubleshootin
g
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
5.5.2 Diagnosing Problems
As previously mentioned, the PC based FS Trawl Systems are more complex than
prior systems to pinpoint a specific fault. The primary emphasis must be placed on
determining initially if the problem can be traced to something other than the specific
FS equipment itself. You must eliminate the cable, pigtail connections, slip
rings and wheelhouse to slip ring cable as the source(s) of the problems.
If the FS system develops a problem (or if it fails completely), and before you start
swapping out FS units, the steps below should be followed:
Check the power supply unit meters. If the system PWR/TTM unit won’t power
up, ensure that all voltage switches are in the correct operating positions (i.e.
ON, and at the proper power level). If the system develops a problem or fails
while operating, then note the voltage and current meter behaviors. If the
current meter jitters, then stop the trawl winch, if rotating, and note any changes
in the meter values or their behavior.
Monitor the System Error Message Log, as described in Section 5.4.4. The
description of the errors may assist in determining the area of the system where
the fault is occurring.
Make an evaluation of whether you consider the fault to be intermittent (i.e.
occurs periodically), or if the fault is “hard”. “STOP” (Icon) operation of the FS
system, turn the PWR/TTM unit off and power back up after a two-minute wait
period. “RUN” (Icon) to restart the FS system. If the system does not run up
properly, consider the fault hard and proceed to the next step.
Disconnect the trawl unit from the trawl cable and re-connect to the FS system
using the test cable. Power up the system and observe if the system powers up
and operates correctly. IF the fault is still “hard”, then the problem will almost
surely be in one of the FS units. If the unit runs up correctly, and does this
several times correctly and runs for a period of time on the test cable, you have
proven that the FS system will operate on the test cable. Some other outside
influence is acting on the system to cause the hard failure. Even if you
evaluated the fault as “intermittent”, running the deployment package on the test
cable would be a step in the fault finding process.
Note!
If a Simrad FS unit is diagnosed as being faulty, then the unit(s)
should be returned to an authorized Simrad service center. ALL
system performance results and a complete description of the
problem should be supplied with the defective unit to assist in
its repair.
88


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad FS20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad FS20 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info