634488
20
Zoom out
Zoom in
Previous page
1/54
Next page
18 | Installation
Figure 2-9 LF3000/LFI3000 Mk2 connections
2.8 Drive unit installation
The relations between drive units, drive unit voltage,
autopilot computer, drive performance and interface to
the steering gear are shown in the tables below.
Refer to the connecting diagram for the different drive
units on page 19 onwards.
Installation instruction for the drive units are found in the
manual for the individual units.
The maximum drive current capability of the AC12 and
AC42 autopilot computers are different. Use the table
below as reference and observe the notes on next page.
HYDRAULIC PUMPS
RAM CAPACITY
MODEL
MOTOR
VOLTS
AUTO-
PILOT
COMPU-
TER
MIN
cm
3
(cu. in.)
MAX
cm
3
(cu. in.)
FLOW RATE
AT 10 bar
cm
3
/min
(cu. in/min)
MAX
PRESSURE
bar
PWR.
CONSUM-
PTION
RPU80
12V
AC12
80 (4,9)
250 (15,2)
800 (49)
50
2,5-6 A
RPU160
12V
AC42
160 (9,8)
550 (33,5)
1600 (98)
60
3-10 A
RPU300
12V
AC42
290 (17,7)
960 (58,5)
3000 (183)
60
5-25 A
RPU300
24V
AC42
290 (17,7)
960 (58,5)
3000 (183)
60
2,5-12 A
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad AC42 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad AC42 in the language / languages: English as an attachment in your email.

The manual is 2,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info