66
Handling and operation
SWW 1500 A1
GB
MT
Setting the nominal temperature
Press the button POWER/MODE
3
and/or
12
repeatedly until, in the dis-
play , the nominal temperature and the indicator LOW blinks for 5 seconds.
Whilst the nominal temperature is blinking in the display
press one of
the buttons +/-
4
and/or
13
to set the desired nominal temperature from
15°C to 27°C. Each press of the button +/-
4
and/or
13
increases or
reduces the nominal temperature by 1°C. Wait approx. 5 seconds until the
nominal temperature is continuously shown in the display . The setting is
now saved and the heating element
9
switches on.
Press the button POWER/MODE
3
and/or
12
again if you want to set the
high heat output (HIGH). In the display the nominal temperature as well
as the indicator HIGH blink for 5 seconds.
NOTICE
As soon as the temperature at the temperature sensor integrated into the
device has reached the set nominal temperature the heating element
9
switches off and in the display the indicator HIGH and/or LOW blinks.
As soon as the temperature falls below the nominal temperature the
heating element
9
switches on again and in the display the indicator
HIGH and/or LOW lights up continuously.
Programming the switch off time
Beforehand, select the desired heating mode (HIGH or LOW) and, if desired,
the nominal temperature (see Chapter “Heating operation” and “Setting the
nominal temperature”).
Press the button AUTO OFF
5
and/or
14
. In the display appears the
indicator for automatic switch off AUTO OFF and the preset time blinks
for 5 seconds.
Whilst the preset time is blinking in the display
press one of the buttons
+/-
4
and/or
13
to set the desired switch off time between 1 hour and
24 hours. As soon as the set heating mode (HIGH or LOW) or the set target
temperature is again indicated in the display , the setting has been accepted
and the appliance switches itself off with the lapse of the time period.
Press the button AUTO OFF
5
and/or
14
again if you want to deactivate
the switch off time. In the display
the indicator AUTO OFF goes out.
Programming the switch on time
Activate the main switch POWER
6
to switch the device on and to shift into
standby operation.
Press the button AUTO ON
2
and/or
11
. In the display appears the
indicator for automatic switch on AUTO ON and the preset time blinks
for 5 seconds.
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Silvercrest SWW 1500 A1 IAN 66900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Silvercrest SWW 1500 A1 IAN 66900 in the language / languages: English, Portuguese, Spanish as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Silvercrest SWW 1500 A1 IAN 66900

Silvercrest SWW 1500 A1 IAN 66900 User Manual - German, Dutch, French, Italian - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info