Safety instructions
Read the operating instructions before using the tool and always observe the safety rules.
Warning
Non-observance of the safety rules while working with the hot air tool may cause a fire,
explosion, electric shock or burns. – The user must take the weather conditions into consid-
eration and avoid working in the rain or moist/damp conditions as this may cause an electric
shock - Exercise care when using the tool in the proximity of combustible materials. Do not
direct the tool at the same place for a prolonged period. - Do not use the tool in the pres-
ence of an explosive atmosphere. -Heat may be conducted to combustible materials that are
out of sight. - Do not leave the tool unattended when in operation.
Personal Protection against electric shock
Avoid touching earthed equipment, such as piping, radiators, cookers, refrigerators. An
incorrectly connected mains lead could cause possible electric shock. - A damaged casing
or an opened unit could cause an electric shock if still plugged in.
Store the tool in a safe place
After use set the tool down on its knock guard and allow it to cool before storing back in its
case. When not in use, tool should be stored in a dry locked room out of the reach of children.
Beware of toxic gases and ignition hazards
Toxic gases may occur when working on plastics, paints varnishes or similar materials. Avoid
breathing in vapours, even when they appear to be harmless. Be aware of fire and ignition
hazards.
Caution power cord
A damaged power cord can lead to an electric shock. - Do not carry the tool by the power
cord and do not use the power cord to pull the plug from the outlet. - Protect the power cord
from heat, oil and sharp edges.
Caution
For your own safety, only use the accessories and attachments that are shown in the oper-
ating instructions or recommended or specified by the manufacturer. Using attachments or
accessories other than those recommended in the operating instructions or catalogue may
result in personal injury.
Repairs
This hot air tool complies with the relevant safety regulations. Repairs should only be per-
formed by a qualified electrician. Failure to observe the operating instructions may result in
injury or damage to you or your place of work. Failure to observe the operating instructions
may turn the tool into a source of danger. Keep these safety warnings in a safe place
Maintenance, Service and Repairs
Before any work on the unit: Remove the tool from the power source - Check the power
cord and plug for any visible damage. - For secure and proper operation, keep the unit and
the ventilation slots clean at all time. - Use only original Sievert accessories. If the tool does
not work after following the trouble shooting guide then unit should be taken to an author-
ized Sievert Service Center.
CE Declaration of conformity
This product complies with the European Directive on Low-Voltage Appliances, 73/23/EEG,
SS-EN 60335 and EMC-Directive 89/336/EEG. This product complies with the latest
standards on mains pollution (EN 61000-3-3, EN 61000-3-2).
Functional Warranty
The Sievert DW2000 has been manufactured with utmost care, tested for proper opera-
tion and safety and then subjected to random sample inspection. The functional warranty
period is 12 months, commencing on the date of sale to the consumer (Proof of purchase
is required for all warranty claims). The warranty shall be met by repair or replacement of
defective parts at our own discretion. The warranty shall not cover damage to wearing parts,
e.g. heating element or power cord, damage or defects caused by improper treatment or
maintenance, nor shall it cover breakage as a result of the product being dropped. Indirect
costs, damage or losses, such as loss of profit, wasted expenses or other consequential
damages are excluded. Claims under warranty shall only be accepted if the product is sent
fully assembled and well packed complete with sales receipt or invoice (date of purchase
and dealer’s stamp) to an authorised Sievert Service Centre.
Trouble shooting
6 7
GB GB
Cause Correction
Defective heating element Insert a new heating element, see page 5
Defective fan Contact Sievert service center
Blocked air flow Clean air intake, see page 4
Electonic unit overheated Turn of the tool for 3 min and clean air intake
Too low incoming voltage
under 90 V ( 160V : 230V version)
Check power supply, push minus button in
off mode to see incoming voltage
Too high incoming voltage
over 130 V ( 250V : 230V version)
Check power supply, push minus button in
off mode to see incoming voltage
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sievert DW 2000 Hot Air Tool at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sievert DW 2000 Hot Air Tool in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 1,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info