28 Examples and HowTos
Examples and HowTos
Canonical Dialing
Canonical Dialing Settings
The following example shows settings suitable for the conversion of given dial strings to canonical
format.
Canonical Dial Lookup
The following example shows settings suitable for recognizing incoming numbers and assigning
them to entries in the local phone book, and for generating correct dial strings from phone book
entries, depending on whether the number is internal or external
Parameter Example value Explanation
Local country code 44 International country code for the UK.
National prefix digit 0 Used in front of national codes when dialled without
international prefix.
Local national code 115 Area code within the UK (here: Nottingham).
Min local num length 7 Number of digits in a local PSTN number (e.g.
3335333 = 7 digits).
Local enterprise node 780 Prefix to access Nottingham numbers from within the
Unify network.
PSTN access code 9 Prefix to make an international call in the UK.
Operator code 0, 7800 Set of numbers to access the local operators.
Emergency number 999, 555 Set of numbers to access emergency services.
Initial extn. digits 2, 3, 4, 5, 6, 8 1
st
digits of numbers that are used for extension
numbers on the local node.
Parameter Example value Explanation
Local code 1 780 Enterprise node prefix (here: Nottingham).
International code 1 +44115943 Equivalent prefix to access numbers on this node
from the PSTN. Here, the prefix used by the PSTN
(DID/DDI: direct inward dialing) is 943, which differs
from the enterprise node prefix used within the enter
-
prise network.
Local code 2 722 Enterprise node prefix (here: Munich).
International code 2 +4989722 Equivalent prefix to access numbers on this node
from the PSTN. Here, the prefix used by the PSTN
for direct inward dialing is identical to the the enter
-
prise node prefix.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Unify OpenStage 15 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Unify OpenStage 15 T in the language / languages: English as an attachment in your email.

The manual is 8,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens Unify OpenStage 15 T

Siemens Unify OpenStage 15 T User Manual - Dutch - 115 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info