Installation and connection en
41
Water pressure:
At least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing
valve ahead.
Inlet rate:
Minimum 10 litres/minute
Water temperature:
Cold water; hot water max. temperature
60 °C.
Warm water connection *
Warm water connection
* depending on model
The dishwasher can be connected
to cold or hot water up to max. 60 °C.
Connection to hot water
is recommended if the hot water can be
supplied by energetically favourable
means and from a suitable installation,
e.g. solar heating system with circulation
line.
This will save energy and time.
The hot water setting ‘:‹‚ allows you
to adjust your appliance optimally
to operation with hot water.
It is recommended to have a water
temperature (temperature of the
incoming water) of at least 40 °C
and no more than 60 °C.
It is not recommended to connect
the appliance to hot water if the water
is supplied from an electric boiler.
Setting hot water:
1. Open the door.
2. Switch on ON/OFF switch (.
3. Hold down programme button #
and press START button `
until •:‹... is indicated on the digital
display.
4. Release both buttons.
The LED for button # flashes and
the digital display h displays the
factory setting •:‹….
5. Press programme button # until
the factory set value ‘:‹‹
is indicated on the digital
display h.
To change the setting:
1. By pressing the 3 button, you can
switch the hot water setting off ‘:‹‹
or on ‘:‹‚.
2. Press START button `.
The set value is saved.
3. Close the door.
Electrical connection
Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing 9:.
The socket must be near
the appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side
to satisfy the relevant safety
instructions.
The connection may be modified by
technicians only.
A power cord extension may be
purchased from customer service
only.