MHG Heiztechnik Montage – Betrieb - Wartung CE1U2354de
24.04.2009
8 Technische Daten
8.1 Grundgeräte RVS…
Bemessungsspannung AC 230 V (± 10%)
Bemessungsfrequenz 50/60 Hz
Maximale Leistungsaufnahme RVS63.283: 11 VA
Absicherung der Zuleitungen max. 10 AT
Speisung und Ausgänge Draht oder Litze (verdrillt oder mit Ader-
endhülse):
1 Ader: 0.5 mm
2
...2.5 mm
2
2 Adern: 0.5. mm
2
..1.5 mm
2
3 Adern: nicht erlaubt
Softwareklasse A
Wirkungsweise nach EN 60730 1.B (automatische Wirkungsweise)
Digitaleingänge H1 und H2 Schutzkleinspannung für potentialfreie
kleinspannungsfähige Kontakte:
Spannung bei offenem Kontakt:
DC 12 V
Strom bei geschlossenem Kontakt:
DC 3 mA
Analogeingang H1, H2 Schutzkleinspannung
Arbeitsbereich: DC (0...10) V
Innenwiderstand: > 100 kΩ
Netzeingang S3, 4 und EX2 AC 230 V (± 10 %)
Innenwiderstand: > 100 kΩ
Fühlereingang B9
Fühlereingänge B1, B2, B3, B12, BX1,
BX2, BX3, BX4
Fühlereingänge BX1…BX4
NTC1k (QAC34)
NTC10k (QAZ36, QAD36)
PT1000 (wahlweise für Kollektor- und Ab-
gasfühler)
0.25 0.5 0.75 1.0 1.5 mm
2
Zulässige Fühlerleitungen (Cu)
Bei Leitungsquerschnitt:
Maximallänge:
20
40 60 80 120 m
Relaisausgänge
Bemessungsstrombereich
Maximaler Einschaltstrom
Maximaler Gesamt-Strom (aller Relais)
Bemessungsspannungsbereich
AC 0.02...2 (2) A
15 A während 1 s
AC 10 A
AC (24...230) V (für potentialfreie Ausgän-
ge)
Triac-Ausgang QX3
Bemessungsstrombereich
ON/OFF Betrieb
Drehzahlsteuerung
Maximaler Einschaltstrom
AC 0.05...2 (2) A
AC 0.05...1.4 (1.4) A
4 A während 1 s
Analog Ausgang U1
Ausgangsspannung
Strombelastung
Ripple
Genauigkeit Nullpunkt
Fehler restlicher Bereich
Ausgang ist kurzschlussfest
U
out
= 0 ... 10.0 V
±2 mA RMS; ±2.7 mA peak
50 mVpp
< ± 80 mV
130 mV
Speisung
Klemmenverdrahtung
Funktionsdaten
Eingänge
Ausgänge
127


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RVS 63.283 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RVS 63.283 in the language / languages: German as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info