555855
40
Zoom out
Zoom in
Previous page
1/288
Next page
Building Technologies 74 319 0619 0 a 17.04.2008 40/288
en
Connection diagrams
A6 Room unit M1 Circulating pump / bypass pump
B1 Flow temperature sensor M2 Heating circuit pump
B2 Boiler temperature sensor M3 Charging pump
B3 Flow temperature sensor for d.h.w. M4 Boiler pump or circulating pump
B31 D.h.w. storage tank temperature sensor / thermostat 1 M5 Collector pump
B32 D.h.w. storage tank temperature sensor / thermostat 2 N1 Controller RVL482
B5 Room temperature sensor S1 Remote operation "Operating mode"
B6 Collector sensor S2 Remote operation "Flow temperature setpoint"
B7 Return temperature sensor U1 Solar sensor
B9 Outside sensor U2 Wind sensor
E1 2-stage or modulating burner Y1 Actuator "Heating circuit"
F1 Limit thermostat
F2 Manual reset safety limit thermostat
Y7 Actuator "D.h.w. circuit" or "Minimum limitation
of boiler return temperature"
LPB Data bus
1
) Multifunctional output
Basic connections on the low voltage side – plants with external heat demand signals
AC 230 V
B5B31 B7B2
B32
B3
DC 0...10 V
B31
2542A01
D1
D2
B3
S2
L
N
B2
B32 U1
+
-
-
DC 0...10 V
MH2
+
U2
B6
LPB
B6
DB
MB A6 MD B9 B1
M
MH1
N1
BM
BM
BM
BM
BM
B
MBM
B
M
BM
B9
A6 B1
B7
S1
B5
L
N
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RVL482 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RVL482 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 2,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info