Settings for automatic operation with 2 comfort periods
Adjustable in operating modes , , and
OK
OK
OK
OK
OK
h
OK
h
OK
° C
OK
OK
h
OK
h
OK
° C
ESC
ESC
/
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
1. OK-button: You access the menu level;
the clock flashes.
2. Setting knob: Clockwise to
menu,
flashes.
3. OK-button: You accept the menu;
the day selection symbol
flashes.
4. Setting knob: Select the days, the working days,
the weekend or the week.
5. OK-button: You save the selection made;
heating period flashes.
6. Setting knob: Counterclockwise to
7. OK-button: Accept
;
comfort period 1 flashes.
7. OK-button: You accept comfort period 1;
start time of comfort period 1
flashes.
9. Setting knob: Set the start time of
comfort period 1.
10. OK-button: You save the input; end time of
comfort period 1 flashes.
11. Setting knob: Set the end time of
comfort period 1.
12. OK-button: You save the input; setpoint of
comfort period 1 flashes.
13. Setting knob: Set the setpoint of
comfort period 1.
14. OK-button: You save the input;
comfort period 2 flashes.
15. OK-button: You accept comfort period 2;
start time of comfort period 2
flashes.
16. Setting knob: Set the start time of
comfort period 2.
17. OK-button: You save the input; end time of
comfort period 2 flashes.
18. Setting knob: Set the end time of
comfort period 2.
19. OK-button: You save the input; setpoint of
comfort period 2 flashes.
20. Setting knob: Set the setpoint of
comfort period 2.
21. Press the ESC-button to return to the
comfort periods menu: Menu item
comfort periods
flashes.
22. Setting knob: To menu item
or
comfort periods
(Change not necessarily required; press the ESC-
button several times to leave the menu level in
several steps, thus returning to the initial display.)
Settings for automatic operation with 1 or 3 comfort periods
Adjustable in operating modes , , and
The procedure to be followed is the same as that for automatic operation with 2 comfort periods. The only
difference being that, in addition, a setpoint for comfort period 3 can be entered (standard setting 21 °C)
Absence / holidays
Adjustable in operating modes , , and
OK
OK
OK
OK
° C
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display
will appear again.
1. OK-button: You access the menu level;
the clock flashes.
2. Setting knob: To
, menu ; flashes.
3. OK-button: Accept
;
symbol
flashes.
4. Setting knob: Set the start (weekday) of your
absence.
5. OK-button: You save the input;
the number of days flash.
6. Setting knob: Set the duration of your absence;
number of days (max. 99 days)
7. OK-button: You save the input;
setpoint
flashes.
8. Setting knob: Set the temperature.
9. Press the ESC-button to return to the menu level;
the clock flashes.
(Change not necessarily required; press the
ESC-button again to return to the initial display)
Siemens / Building Technologies / HVAC Products B2218en 26.03.2007
Special day
Adjustable when this operating mode is selected
Special day with 24-hour mode and one comfort
period.
Start of comfort period, end of comfort period and
temperature setpoint can be set individually by
OK-button and setting knob.
Press the ESC-button to return to the initial display
Retrieving the default values
Press the button behind the small opening for at
least one second, thus resetting the user-specific
settings to their default values
(the heating engineer settings will remain
unchanged).
The clock starts at 12:00.
When making a reset, all display fields will light up.
Default values
Factory settings for heating
Operating mode
Start of continuous operation 00:00 00:00 00:00
End of continuous operation 24:00 24:00 24:00
Setpoint of comfort mode 19 °C
Setpoint of economy mode 16 °C
Setpoint frost protection 5 °C
Setpoint absence
12 °C
Operating mode
Selected periods
Start of period 1 07:00 06:00 06:00
End of period 1 23:00 08:00 08:00
Start of period 2 17:00 11:00
End of period 2 22:00 13:00
Start of period 3 17:00
End of period 3 22:00
Setpoint of period 1 19 °C 19 °C 19 °C
Setpoint of period 2
20 °C 20 °C
Setpoint of period 3
21 °C
Setpoint
see above
Default values
Factory settings for cooling
Operating mode
Setpoint 23 °C 23 °C 29 °C 35 °C
Setpoint
absence
30 °C
Changing the batteries
2 Alkaline-Batteries Type AA 1,5 V
When this symbol appears, the batteries must
be replaced within 3 months.
1. Remove controller from its base.
2. Open battery compartment at the rear and
replace the batteries.
3. Close battery compartment and replace the
controller.
Note:
When changing the batteries, the current data are
maintained for a maximum of one minute.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens REA23.03RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens REA23.03RF in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens REA23.03RF

Siemens REA23.03RF User Manual - German - 2 pages

Siemens REA23.03RF User Manual - French - 2 pages

Siemens REA23.03RF Installation Guide - All languages - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info