Alternative: Driving the circulating pump/
boiler
DIP
switch
!
For this application:
Step 1: Operate the DIP switch
Power off the RDE-MZ6.
Open the cover of the controller and set the
DIP switch to position to 1 (ON). This means
that zone 6 is now reconfigured for the
circulating pump/boiler (default is OFF)
Switch no.
1
Application
All valves (zone 1 to 6)
OFF
Pump/boiler (zone 6 only)
ON
Step 2: Making connections
Connect zone 1 to zone 5 with valves or
actuators.
Connect zone 6 to the circulating pump or
boiler.
Step 3: Learning
Power on the RDE-MZ6.
Press and hold the RESET button for more
than 10 seconds to make a complete reset.
To pair zones 1 to 5, follow either option 1 or
2 in the previous section.
Zone 6: No pairing is required and the button
is disabled.
Functionality
The output of zone 6 is enabled if either one
or more of the remaining zones is turned on.
Zone 6 will turn off if all remaining zones are
turned off (same as LED indication).
Note:
Always power off the receiver before
operating the DIP switch.
Whenever a DIP switch has changed its
position, it is highly recommended to make a
complete reset and perform wireless learning
again.
Controller’s LED indication
State of controller State of LED
Power up (or reset) All 6 red and green LEDs flash
alternately for 5 seconds and then
extinguish.
Note: If the receiver zone was
previously programmed, it will
immediately change to constantly
red.
Learning mode
Successful learning
mode
The respective zone’s red and
green LEDs flash alternately.
The respective green LED will flash
for 10 minutes if controller learning
is successful.
Signal ok and output
status change
For boiler or pump
configuration
The respective zone’s green LED is
constantly lit. If the output status
changes, the green LED will flash
for 3 seconds and then changes
back to constantly green.
Zone 6:
Green LED is lit when relay is
energized.
Green LED is extinguished when
relay is deenergized.
Fail to receive
wireless data
If the respective zone of the
controller fails to receive wireless
data, the red LED will start to flash
after 125 minutes.
If RDE-MZ6 signal is recovered, it
will return to the previous LED
state.
Respective
zone has
no ID
The respective LED is extinguished.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RDE-MZ6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RDE-MZ6 in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens RDE-MZ6

Siemens RDE-MZ6 User Manual - German - 4 pages

Siemens RDE-MZ6 User Manual - Dutch - 3 pages

Siemens RDE-MZ6 User Manual - French - 3 pages

Siemens RDE-MZ6 Installation Guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info