813775
60
Zoom out
Zoom in
Previous page
1/72
Next page
10
Anhang
Objektliste
58 | 72
A6V11471220_en--_e
PDT_UNSIGNE
D_CHAR
U8 /
DPT_Value_1_
Ucount
d.ind
Index-Discovery
per LTE-Lesen auf
diese Eigenschaft
T060.0601_EN_SARB
_Data_Aquisition:
7.1.2.10.1
KNX Norm, Kapitel 3-
5-1,
PID_OBJECT_INDEX
TempOutside
Eff
15
5
1
V16Z8 /
DPT_TempHVA
CAbs_Z
R
IR.in
d
Vom Automationsge-
rät gelieferter Außen-
temperaturwert (°C)*)
Feldbeschreibung
Temperaturwert
Sup.Unit Default Tem-
perature Outside
M °C. cs STA-
TUS Bitset M
Bit 0: OutOfService
Sensor außer Betrieb
M t/f false
Bit 1: Fault Sensorwert
ist nicht lesbar M t/f
false
Bit 2: Overridden
Sensor ist vorüberge-
hend übersteuert O t/f
false Bit 3: InAlarm
Sensor ist im Alarm-
betrieb O t/f false
Bit 4: AlarmUnAck
Quittierung des
Alarms O t/f false
Alle anderen Bits sind
reserviert.
TempRoo-
mEff
15
7
1
V16Z8/PDT_G
ENE-
RIC_03/DPT_Te
mpHVAC Abs_Z
R
IR.in
d
Vom Automationsge-
rät gelieferter resultie-
render (ggf. gemittel-
ter) Raumtempera-
turwert (°C)*)
Tem-
pRoomSetp-
AbsEff
16
1
1
V16Z8 /
DPT_TempHVA
CAbs_Z
R
IR.in
d
Absolute, vom Nutzer
gewünschte Raum-
temperatur, berechnet
aus HVACMode und
TempRoomSetpUserO
ffset
=> cASA-[T022.S031-
2]-SARB-Data-
Mapping-HVAC
HVACMo-
deEff
16
3
1
N8Z8 /
DPT_HVACMo
de_Z
R
IR.in
d
Effektiver HVACMo-
de, der vom Automa-
tionsgerät auf der
Grundlage der
HVACModeUser-
Anforderung, des
Planers usw. be-
rechnet wird.
ComfortPro-
longEff
16
8
1
DPT_State
R
IR.in
d
Information, ob die
Komfortverlängerung
aktiv ist oder nicht
0 = inaktiv; 1 = aktiv
=> cASA-[T022.S031-
2]-SARB-Data-
Mapping-HVAC
TmpFanMo-
de
20
8
1
N8 /
PDT_ENUM8
R
IR.in
d
TmpFanMode bezieht
sich auf die optionale
Prozesseingabe-
Eigenschaft von
AB UHD, um am
Raumgerät (z. B. RU-
B) anzuzeigen, ob ein
temporärer HRV-
Lüfterbetrieb aktiv ist.
Aufzählungswert
- 0: Ohne
- 1: FanBoostModus
- 2: FirePlaceMode
- 3: KitchenHoodMode
TmpFanMo-
deRemain-
Time
20
9
1
U16 /
DPT_TimePerio
dSec
R
IR.in
d
TmpFanModeRemain
Time bezieht sich auf
die optionale Pro-
zesseingabe-
Eigenschaft von
AB UHD
=> cASA-[T022.S035-
2I055] Lüfterbetrieb:
Intensivlüf-
tung/Kamin/Dunstabzu
gshaube
6155880
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens POS8.4420-109 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens POS8.4420-109 in the language / languages: German as an attachment in your email.

The manual is 4.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info