Prior to installation
D
If the extractor hood is operating in
exhaust-air mode at the same time as a
flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
there must be an adequate air supply
which the fireplace requires for combusti-
on.
Safe operation is possible if the partial
vacuum in the installation room of the fire-
place does not exceed 4 Pa (0.04 mbar).
This can be achieved if the combustion air
is able to flow through non-lockable ope-
nings, e.g. in doors, windows and in con-
junction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air supply is inadequate, there is a
risk of poisoning caused by combustion
gases being drawn back into the room.
Note: When assessing the air supply,
always take into account the entire ventila-
tion system in the house. This rule does
not apply when using cooking appliances,
e.g. hob or gas cooker.
The fan is designed for installation on
sloping tiled roofs only.
The slope of the roof must be at least 10°.
The fan must not be installed on flat
roofs or Eternit roofs.
The fan may be installed by a qualified
roofer only.
The fan must be attached at least 2 m
from the extractor hood.
Do not attach the outer wall fan near
windows, doors or patios.
When attaching the outer wall fan,
ensure that
–residents and neighbours are not
disturbed by noise and odours,
–it is accessible for maintenance and
repairs.
The plug-and-socket connections of
the electric cables must be located inside
the building.
Do not reduce the 150 mm diameter of
the pipes connected to the extractor hood.
An additional silencer for 150 mm l pipes
is available as an optional accessory from
specialist outlets.
Weight: 7,0 kg.
We reserve the right to construction changes within the
context of technical development.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens lx 5 d 565 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens lx 5 d 565 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info