2.8 Menu bar
LOGO!Soft Comfort Online Help
122 Operating Instructions, 11/2017
The following VM addresses are occupied for special purposes:
VM Address
Reserved for
Range
984
Diagnostic Bits Array
1 Byte
985 "Year" of Real Time Clock (RTC) 1 Byte
986
"Month" of RTC
1 Byte
987
"Day" of RTC
1 Byte
988
"Hour" of RTC
1 Byte
989
"Minute" of RTC
1 Byte
990
"Second" of RTC
1 Byte
The LOGO! Base Module can share the following data with S7/Modbus by VM address:
Data Type
Number
Memory Type
Digital input
24
Byte
Digital output
16
Byte
Digital flag
27
Byte
Analog input
8
Word
Analog output
2
Word
Analog flag
16
Word
Value parameter
**
**
Actual value
**
**
The length (Byte, Word, or DWord) indicates the number of bytes in the VM area required by
the parameter.
LOGO! Base Module can also share the time and date information with SIEMENS SIMATIC
S7/Modbus compatible devices and HMI devices using VM addresses from 991 to 1002.
LOGO!Soft Comfort links the block parameters that you specify in the Variable Memory
Configuration dialog with a VM address.
Not all of the VM area is available for configuration. LOGO!Soft Comfort reserves some
bytes of the VM area. You cannot specify more than 64 parameters. If you attempt to specify
more than 64, LOGO!Soft Comfort displays a failed operation message.
After the data transfer from a LOGO! Base Module to LOGO!Soft Comfort, you can view only
analog values within the range of -32768 to 32767 on LOGO!Soft Comfort. If an analog value
exceeds the value range, then only the nearest upper limit (32767) or lower limit (-32768)
can be displayed.
Parameter settings
Function Block
Data type
Read/Write
Parameter settings in
LOGO!Soft Comfort
Parameter settings on a partner
device
On-Delay
Current Time
VW
R
On-Delay VW R/W
Unit: Seconds
Value range: 0 to 9999
Unit: Minutes or Hours
Value range: 0 to 5999
122


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LOGO Soft Comfort Online Help at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LOGO Soft Comfort Online Help in the language / languages: English as an attachment in your email.

The manual is 12,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens LOGO Soft Comfort Online Help

Siemens LOGO Soft Comfort Online Help User Manual - German - 428 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info