The Block column lists the parameters for SFBs in the current program. The Parameter
column provides a select list of the parameters of the corresponding block. The Type column
displays the data type of the selected parameter. The Address column is also configurable.
You can use it to identify the VM address used to save a parameter value.
The icon next to a parameter name indicates the property of this parameter:
The parameter value is a setting value and is writable.
The parameter value is an actual value and is read-only.
Although the parameter value is an actual value, you can still change the value.
NOTE:
Only the Counter parameter of Up/Down counter has such a flag.
The parameter value is referenced from an actual value of another already
-
programmed function block.
Note that if no flag appears, then the parameter value is a system value and r
emains read-
only.
Within the parameter VM mapping window, you can achieve the following tasks:
Select multiple record lines by pressing the
Ctrl
key or
Shift
key and clicking the ID of the
desired line.
Insert a down line by pressing the
Enter
key
on the last cell of the desired line.
Insert an up line by clicking the ID of the desired line and pressing the
Insert
key, or
right-clicking the desired line to add a new row.
Delete a line by clicking the ID of the desired line and pressing the
Delete
key, or
right-clicking the desired line to delete an existing row.
You cannot change the parameter type and must configure a unique address for each
parameter. The range for a parameter address is from 0 to 850. If the value you input
exceeds this range, inputs and outputs will be modified to certain VM addresses
automatically.
119


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LOGO Soft Comfort Online Help at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LOGO Soft Comfort Online Help in the language / languages: English as an attachment in your email.

The manual is 12,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens LOGO Soft Comfort Online Help

Siemens LOGO Soft Comfort Online Help User Manual - German - 428 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info