Installation instructions en
13
12.6 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING‒Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡The connection data can be found on the rating
plate. →Page9
¡The connecting cable is approx.1.30m long.
¡This appliance complies with the EC interference
suppression regulations.
¡The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡Do not connect the appliance to the power supply
during installation.
¡Ensure that the protection against contact is guaran-
teed during installation.
12.7 General information
Follow these general instructions during the installation.
¡For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
12.8 Installation
Checking the unit
1. Check whether the fitted unit is level and has suffi-
cient load-bearing capacity.
The max. weight of the appliance is 18kg.
Note:Note the furniture manufacturer's specifica-
tions with regard to the load-bearing capacity of the
fitted unit.
2. Ensure that the fitted unit is heat-resistant up to
90°C.
3. Ensure that the fitted unit is still stable after the cut-
outs have been made.
4. Ensure that the fitted unit complies with the following
dimensions:
Width 600mm
Depth Min. 320mm
With lowering frame:
Min.350mm
Position Min. 390mm
With CleanAir circulat-
ing-air set, min. 600mm
Wall thickness 16mm or 19mm
Preparing the units
Requirement:The unit is suitable for the installation.
→"Checking the unit", Page13
1. Cover the hob to prevent damage.
2. Ensure that the stability of the fitted unit is guaran-
teed after the cut-outs have been made.
3. If the cabinet is less than 320mm deep, remove
part of the back panel.
4. Create the cut-out for the pipe connection.
5. If the cabinet base is in place, remove it.
6. Remove any shavings.
7. Use the enclosed mounting part to mark the fasten-
ing points on the inside of the cabinet and use a
bradawl to make indentations where the holes are
to be.
≥170
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LI97SA531 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LI97SA531 in the language / languages: English as an attachment in your email.

The manual is 8.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens LI97SA531

Siemens LI97SA531 User Manual - German - 20 pages

Siemens LI97SA531 User Manual - Dutch - 20 pages

Siemens LI97SA531 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info