791179
7
Zoom out
Zoom in
Previous page
1/24
Next page
Basic operation en
7
7.4 Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
1. Press ⁠repeatedly until LED4 lights up in the LED
display for intensive mode1.
2. Press ⁠repeatedly until LED5 lights up in the LED
display for intensive mode2.
aAfter approx. 6 minutes, the appliance automatically
switches to fan setting 3.
7.5 Switching off intensive mode
To select a fan setting of your choice, press ⁠.
7.6 Switching on the fan run-on
During the fan run-on, the appliance continues to run
for a short time and then switches off automatically.
Note:Further settings are available in the HomeCon-
nectapp.
Requirement:The appliance is switched on.
Press ⁠.
aThe fan run-on starts at fan setting1.
aThe Ambient Light remains switched on for ap-
prox.10minutes.
aThe glass panel remains extended halfway.
aThe appliance switches off automatically after ap-
prox. 10 minutes.
aThe glass panel moves downwards and the appli-
ance closes.
7.7 Switching on automatic mode1
The optimum fan setting is set automatically using a
sensor.
Press ⁠.
Note:In automatic mode, the Guided Air function is al-
ways switched on.
7.8 Switching off automatic mode1
Press ⁠.
aThe appliance starts at fan setting2.
aThe ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
aAutomatic mode runs for a maximum of four hours.
Note:Further settings are available in the HomeCon-
nectapp.
7.9 Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note:This function is only available in the HomeCon-
nectapp.
If the interval ventilation is switched on, LED1 flashes.
7.10 Sensor control1
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡Default setting: Fan setting3
¡Lowest setting: Fan setting1
¡Highest setting: Fan setting5
7.11 Setting the sensor control1
Requirement:The appliance is switched on.
1. Press and hold ⁠and ⁠for approx.three seconds.
2. Press ⁠or ⁠ to change the setting.
3. Press ⁠ to save the setting.
Or wait approx. fiveseconds until the setting is
saved automatically.
aA signal tone sounds as soon as the selected set-
ting is saved.
7.12 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched on.
1. Press and hold ⁠and ⁠for approx. 3 seconds.
To set circulating-air mode (Clean Air Standard
circulating-air set or Clean Air Plus circulating-air
set), press and hold ⁠/ ⁠ until LED2 lights up in
the LED display.
To set circulating-air mode (regenerable filter),
press ⁠/ ⁠ until LED3 lights up in the LED dis-
play.
To convert the electronic control back to opera-
tion without the air recirculation filter, press ⁠/ ⁠
until LED1 lights up on the LED display.
2. Press ⁠ to save the setting.
Or wait approx. fiveseconds until the setting is
saved automatically.
aA signal tone sounds as soon as the selected set-
ting is saved.
7.13 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡After switching off the appliance, the upper two LEDs
for the grease filter's saturation indicator and/or the
lower two LEDs for the odour filter's saturation indic-
ator flash in the left hand control panel.
¡A signal sounds repeatedly.
Press ⁠.
aThe saturation indicator is reset.
1Depending on the appliance specifications
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LD88WMM66 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LD88WMM66 in the language / languages: English as an attachment in your email.

The manual is 9.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens LD88WMM66

Siemens LD88WMM66 User Manual - German - 24 pages

Siemens LD88WMM66 User Manual - Dutch - 24 pages

Siemens LD88WMM66 User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info