623051
5
Zoom out
Zoom in
Previous page
1/16
Next page
Operating the appliance en
5
1Operating the appliance
Operating the appliance
These instructions apply to several appliance variants. It
is possible that individual features are described which
do not apply to your appliance.
Note: Switch on the extractor hood when you start
cooking and switch it off again several minutes after you
have finished cooking. This is the most effective way of
removing the kitchen fumes.
Control panel model 1
Setting the fan
Switching on
Touch the # symbol.
The fan starts at setting ƒ.
Touch the + or - symbol to alter the fan speed.
Switching off
Touch the # symbol.
Intensive setting
You can use the intensive setting if there is a large
build-up of odours and fumes/vapours.
Touch the + symbol whilst the fan is at setting .
This activates intensive setting 2. Touch the +
symbol once again to activate intensive setting ƒ2.
After approximately six minutes, the electronics
automatically reduce the fan to a lower setting . If you
want to end the intensive setting before the preset time
expires, touch the - symbol until the required fan setting
is reached.
Boost function
The boost function is a short-term maximum power
setting which can be activated at any fan setting.
Touch the & symbol. After approximately 20 seconds,
the fan switches back to the previously set fan setting.
Fan run-on time
Touch the x symbol.
After approximately 10 minutes, the fan switches off
automatically.
Lighting
The lighting can be switched on and off independently
of the fan.
Touch the = symbol.
Setting the brightness
Press and hold the = symbol until the desired
brightness is reached.
Saturation display
When the metal grease filters or the activated charcoal
filter are/is saturated, an audible signal sounds for
approximately four seconds after the fan is switched off.
In addition, the corresponding symbol appears on the
display:
Metal grease filter:!
Activated charcoal filter: "
If you have not yet done so, the metal grease filters
should be cleaned or the activated charcoal filter
changed.
For instructions on how to clean the metal grease filters,
please refer to the section Cleaning and maintenance.
The saturation indicators can be reset while they are
flashing. To do this, touch the - symbol.
Switching over the indicator for circulating-air mode
For circulating-air mode, the electronic control must be
switched over accordingly:
The extractor hood must be connected and switched
off.
Touch and hold the # and x symbols at the same
time, until the " indicator lights up for circulating-
air mode "Starter Set". Repeatedly pressing and
holding this button combination causes the "
indicator to light up for the "CleanAir" circulating-air
module.
Repeatedly pressing and holding this button
combination switches the electronic control back
over to ducted operation (! indicator).
Audible signal
Switching on the audible signal
When the fan is switched off, press and hold the # and
+ symbols simultaneously for approximately three
seconds. An audible signal sounds as an
acknowledgement.
Switching off the audible signal
Repeat the "Switching on the audible signal" process.
LQW
Explanation
#
Fan on/off
=
Light on/off/dimming
- Reduces the fan settings/fan run-on time
+ Increases the fan settings/intensive setting 1, 2
&
Boost function (short-term maximum power)
x
Fan run-on
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LC91BA572 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LC91BA572 in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens LC91BA572

Siemens LC91BA572 Usermanual and installation guide - German - 16 pages

Siemens LC91BA572 Usermanual and installation guide - Dutch - 16 pages

Siemens LC91BA572 Usermanual and installation guide - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info