Optimum performance of the extractor
hood:
Short, smooth extraction pipe.
As few pipe bends as possible.
Largest possible pipe diameter (prefera-
bly 150 mm ø) and large pipe bends.
Round pipes:
We recommend
for single-motor model,
inner diameter of at least 120 mm
for double-motor model.
inner diameter of at least 150 mm
Flat ducts must have an inner cross-
section equivalent to round pipes
which have an inner diameter of
120/150 mm.
120 mm l approx. 113 cm
2
150 mm l approx. 177 cm
2
If pipe diameters differ: use sealing
strip.
Ensure an adequate air supply for
exhaust-air mode.
Pipe connection
Extractor hoods with 120 mm Ø air
outlet:
100 mm Ø extraction pipe
Insert the reducing connector (see optio-
nal accessories on the last page) into the
air-pipe connector and then attach the
exhaust-air pipe.
120 mm Ø extraction pipe
Attach the exhaust-air pipe directly to
the air-pipe connector.
Extractor hoods with 150 mm Ø air
outlet:
150 mm l extraction pipe
Screw the reducing connector (see
optional accessories on the last page)
onto the air outlet.
Attach the extraction pipe to the redu-
cing connector.
150 mm l extraction pipe
Attach the exhaust-air pipe directly to
the air outlet..
If a one-way flap has been fitted, con-
duct a performance test.
Extractor hoods with rectangular air
outlet:
Screw the enclosed
air-pipe connector
over the air outlet.
Recirculated
air mode
The air cleaned by an additional activa-
ted carbon filter is conveyed back into
the room.
In recirculated air mode the exhaust ope-
ning must be protected by a grille (see
optional accessories on the last page) in
order to prevent a mechanical or electri-
cal hazard.
Prior to installation
9000.022 567.qxd 06.09.2006 11:36 Uhr Seite 12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens LB 75564 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens LB 75564 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info