32
Fault Possible cause Remedial action
The refrigerating unit
is switching on more
frequently and for
longer.
Appliance opened
frequently.
Do not open the appliance
unnecessarily.
The ventilation
openings have been
covered.
Remove obstacles.
Large
quantities of fresh
food are being frozen.
Do not exceed max. freezing
capacity.
The frozen food is
thawing.
The ambient
temperature is below
+16° C. The
refrigeration unit is
starting less
frequently.
Increase the ambient temperature
(above +16° C).
Fig. 2/B Appliances with room
temperature switch: To switch on,
press the room temperature switch.
Mark “0” is no longer visible.
The light inside the appliance is lit
at a reduced luminosity.
Appliance has no
refrigeration capacity.
The temperature
controller is in position
“0”.
Turn the temperature controller from
position “0”. Fig. 2/A
Power failure.
The fuse has been
switched off.
The mains plug has
not been inserted
properly.
Check whether the power is on,
check the fuses.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens ki24lv21ff at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens ki24lv21ff in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens ki24lv21ff

Siemens ki24lv21ff User Manual - English, German, Dutch, French, Italian - 116 pages

Siemens ki24lv21ff User Manual - Polish - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info