Description of new and updated functions
Amendment to "Call signalling and number assignment"
Gigaset IP Phones / IM-BELG EN / A31008-xxxx-xxxx-x-xxxx / description.fm / 3/23/09
Version 4, 29.10.2007
Size of the port number range:
The difference between the port numbers must be at least 6 if you permit two simulta-
neous VoIP calls on your phone. It must be at least 4 if you only permit one VoIP call
(
£ user guide for your phone, Web configurator Settings ¢ Telephony ¢ Audio).
The lower of the port numbers in the range (in the left-hand field) must be an even
number. If you enter an odd number, the next lowest even number will be selected auto-
matically (e.g. if you enter 5003, then 5002 is set automatically).
The default port number for voice transmission is 5004.
Use random ports = Yes
SIP port
¤ Enter the port number range from which the SIP port is to be dialled.
¤ Enter the lowest port number in the port number range in the left-hand field and the
highest number in the right-hand field (numbers between 1024 and 49152).
This port number range must not overlap the range specified for RTP port.
The default range is 5060 to 5076.
RTP port
¤ Specify a range of port numbers from which the RTP ports are to be dialled.
¤ Enter the lowest port number in the port number range in the left-hand field and the
highest number in the right-hand field.
The default range is 5004 to 5020.
¤ Now select Set to save your settings.
Amendment to "Call signalling and number assignment"
The section amends the sections "Accepting calls", "Web configurator – Assigning send and receive
numbers to handsets" and "Web configurator – Assigning receive numbers to the answering machine"
in the user guide for your Gigaset VoIP phone.
Signalling incoming calls
If you have not assigned any receive numbers, either to the answering machine or the reg-
istered handsets, calls to all connections will be signalled on all handsets.
If you have assigned receive numbers, your handset will only indicate calls to receiving
numbers assigned to this handset. Please note the following cases:
u If the phone number is not assigned to a handset or an answering machine as a receive
number, all calls to this number are signalled on all handsets.
u If the phone number is not assigned to a handset, but is assigned to the answering
machine, the call is not signalled on any handset and is accepted by the answering
machine.
u Calls to your phone's IP address are signalled on all handsets.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Gigaset S685 IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Gigaset S685 IP in the language / languages: English as an attachment in your email.

The manual is 0,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens Gigaset S685 IP

Siemens Gigaset S685 IP User Manual - English - 280 pages

Siemens Gigaset S685 IP User Manual - German - 202 pages

Siemens Gigaset S685 IP Additional guide - German - 43 pages

Siemens Gigaset S685 IP User Manual - German - 2 pages

Siemens Gigaset S685 IP Additional guide - Dutch - 42 pages

Siemens Gigaset S685 IP User Manual - Dutch - 287 pages

Siemens Gigaset S685 IP User Manual - Dutch - 80 pages

Siemens Gigaset S685 IP Additional guide - French - 42 pages

Siemens Gigaset S685 IP User Manual - French - 288 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info