1793
13
Zoom out
Zoom in
Previous page
1/41
Next page
10
First Steps
Gigaset C450 IP / IM-Nord EN / A31008-M1713-R201-3-7643 / starting.fm / 01.03.2007
Version 4, 16.09.2005
Making settings for VoIP
telephony
Before you can use the Internet (VoIP) to
phone any other users on the Internet, the
fixed network or the mobile phone net-
work, you need the services of a VoIP pro-
vider who supports the VoIP SIP standard.
Precondition: You have registered with a
VoIP provider (e.g. via your PC) and set up
an account.
The following phone settings are neces-
sary in order for you to use VoIP. You will
receive all information from your VoIP pro-
vider.
u Your user name with the VoIP provider,
if this is required by the VoIP provider
u Your registration name
u Your password with the VoIP provider
u VoIP provider general settings
The connection wizard will help you with
the settings.
Starting the connection wizard
Precondition: The base station is con-
nected to the mains power supply and the
router. Your router is connected to the
Internet.
Tip: If VoIP (IP) is activated as the default
connection for your phone (default set-
ting page 25), the phone will attempt to
make a direct connection to the server
belonging to your VoIP provider after the
connection wizard is closed. If incorrect/
incomplete information means that the
connection cannot be made, messages
will be displayed (page 11).
Once the handset battery is sufficiently
charged, the message key f on the hand-
set will flash (around 20 minutes after you
have put the handset in the charging cra-
dle).
¤ Press the message key f.
You will see the following display:
§Yes§ Press the display key to start
the connection wizard.
~ Enter the system PIN of the
base station (the default is
0000) and press
§OK§.
Downloading VoIP provider data
The phone establishes a connection with
the Siemens server on the Internet. Pro-
files with general access data for various
VoIP providers can be downloaded here.
The message Select country is displayed.
After changing the display:
q Select country and press
§OK§.
Select provider is displayed.
After changing the display:
q Select VoIP provider and press
§OK§.
The necessary data for your VoIP provider
is downloaded and saved on the phone.
Please note:
Your phone is preconfigured for dynamic
assignment of the IP address. In order for your
router to "recognise" the phone, dynamic IP
address assignment (the router's DHCP server)
must also be activated on the router.
Please note:
The connection wizard will also start automat-
ically if you try to establish a connection via
the Internet, before you have made the neces-
sary settings.
You can also call up the connection wizard at
any time via the menu (page 15).
Please note:
If the data for your VoIP provider is not avai-
lable for download, you must make the neces-
sary settings with the Web configurator at a
later stage (page 26).
Press the display key §Back§ to carry out the fol-
lowing steps of the connection wizard
(see "Entering VoIP user data").
Start VoIP
Connection
Assistant?
§§§§No§§§§ §§§§§Yes§§§§
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Gigaset C450 IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Gigaset C450 IP in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens Gigaset C450 IP

Siemens Gigaset C450 IP User Manual - German - 41 pages

Siemens Gigaset C450 IP User Manual - German - 117 pages

Siemens Gigaset C450 IP User Manual - Dutch - 89 pages

Siemens Gigaset C450 IP User Manual - French - 127 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info