300755
12
Zoom out
Zoom in
Previous page
1/24
Next page
12
AS180-AS185 / IRL / A31008-M2002-V101-2-7619 / main.fm / 03.06.2009
Software reset
MENU ¢ Settings ¢ OK ¢ Base ¢ OK
¢ Base Reset ¢ OK
Hardware reset
Disconnect the power cord from the base station.
H
old down the registration/paging key
(
¢ page 1) on the base station while reconnect-
ing the power cable to the base station. Release
th
e key after approximately 5 seconds.
Repeater mode
With a repeater you can increase the range of your
base station. You will need to activate repeater
mode (
¢ page 17). Repeater mode and Eco mode
or Eco mode+ (
¢ page 1) cancel each other out.
Operating the base station on
the PABX
The following settings are only necessary if your
PABX requires them, see the user guide for your
PABX.
When entering the digits, enter them sl
owly one
after the other.
Changing the dialling mode
MENU ¢ 4 I O 1 1 ¢ The number for the set dial-
ling mode flashes: 0 = touch tone dialling (DTMF);
1 = dial pulsing (DP) ¢ enter number ¢OK.
Setting recall
MENU ¢ 4 I O 1 2 ¢ The number for the current
recall flash
es: 0 = 80 ms; 1 = 100 ms; 2 = 120 ms;
3 = 400 ms; 4 = 250 ms; 5 = 300 ms; 6 = 600 ms;
7 = 800 ms ¢ enter number ¢ OK.
Changing pause after line seizure
You can set the length of the pause inserted
between pressing the talk key
c and sending the
phone number.
MENU ¢ 4 I O 1 O ¢ The number for the current
pause length flashes: 1 = 1 sec.; 2 = 3 sec.; 3 = 7 sec.
¢ enter number ¢ OK.
Changing the pause after the recall key
MENU ¢ 4 I O 1 4 ¢ The number for the current
pause length flashes: 1 = 800 ms; 2 = 1600 ms;
3 = 3200 ms ¢ enter number ¢ OK.
Appendix
Entering letters/characters
Press the relevant key the number of times indi-
cated.
Briefly
press the hash key # to switch from
"Abc" to "123" mode, from "123" to "abc" mode and
from "abc" to "Abc" mode.
Standard characters
1) Space
Specifications
Recommended batteries
Technology: Nickel-metal-hydride (NiMH)
Size: AAA (Micro, HR03)
Voltage: 1.2 V
Capacity: 400–800 mAh
We recommend the following types of battery:
GP 550/700 mAh
Yuasa Phone 700/800 mAh
Peacebay 550/650 mAh
(Valid at the time of going to press)
The handset is supplied with recommended batter-
ies.
Base station power consumption
General specifications
1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x 12x 13x 14x
1
1 £ $ ¥ ¤
2
a b c 2 ä á à â ã ç
I
d e f 3 ë é è ê
4
g h i 4 ï í ì î
5
j k l 5
L
m n o 6 ö ñ ó ò ô õ
M
p q r s 7 ß
N
t u v 8 ü ú ù û
O
w x y z 9 ÿ ý æ ø å
Q
. , ? ! 0 + - : ¿ ¡ " ; _
P
* / ( )
< = > %
#
Abc
-->
123
123
-->
ab
c
# @ \ & §
In standby mode
– Handset in base station
– Handset outside base station
approx. 1.3 W
approx. 1.3 W
During a call approx. 1.5 W
DECT standard is supported
GAP standard is supported
Range up to 300 m outdoors
up to 50 m indoors
Base station power supply 230 V ~/50 Hz
Environmental conditions
in operation
+5°C to +45°C, 20% to
75% relative humidity
1)
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens gigaset as180 trio at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens gigaset as180 trio in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens gigaset as180 trio

Siemens gigaset as180 trio User Manual - Dutch - 16 pages

Siemens gigaset as180 trio User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info