Building Technologies A6V10393190_c_en_--
Fire Safety
2014-05-28
Appendix C: History log
Message Meaning
Fire alarm
Zone #
Zone # has triggered an alarm.
Fault
Zone # Zone # is in fault state.
Isolation
Zone #
Zone # was disabled.
Fault
Output # Output # is in fault state.
Fault
AUX 24V output
Auxiliary 24 V output is in fault state.
Isolation
Output # Fire output # was disabled.
Active
Output #
Output # is activated when V1 / V2 is running.
Isolation
Fault dialer
'Fault dialer' outputs were disabled.
Isolation
Alarm dialer 'Alarm dialer' outputs were disabled.
Isolation
Sounder outputs Sounder outputs were disabled.
Isolation
EVAC sounder NL 'EVAC sounder NL' outputs were disabled.
Fault
Mains power
Fault in 230 V (or 110 V) power supply.
Fault
Battery
Fault in the battery power supply.
Fault
External PSU Fault in external power supply unit.
Fault
Earth fault Grounding fault.
Fault
Set date & time Date and time was not set.
Input
Input #
Reset
Panel has been reset when get signal from input.
Input
Input #
Level 2 access Panel is into access level 2 when get signal from input.
Input
Input #
Alarm and fault dialer isolated
Isolation of the output 'Alarm dialer' and 'Fault dialer' when get signal
from input.
Input
Input #
Manned operation
Panel is in 'Manned' mode when get signal from input.
Input
Input #
Alarm dialer fault The output 'Alarm dialer' is in fault state when get signal from input.
Input
Input #
Alarm dialer confirmation received Alarm dialer confirmation received when get signal from input.
Input
Input #
Panel is in 'Alert' mode when get signal from input.
92


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens FC122-ZA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens FC122-ZA in the language / languages: English as an attachment in your email.

The manual is 3,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info