652205
16
Zoom out
Zoom in
Previous page
1/20
Next page
12
en
VI.
Electrical connection 230 V AC
To guarantee compliance to relevant safety regulations, an
all-pole separator must be fitted during installation. The con-
tact opening must be at least 3 mm.
If the appliance is connected to the power supply by a plug,
the disconnecting device is not required if the plug is acces-
sible to the user.
Appliances fitted with plugs may only be connected to cor-
rectly earthed electrical sockets. Do not use multiway adap-
tors or pushon terminal strips.
Do not connect the appliance to the power supply until it is
mounted on the wall and filled with water.
Attention!
Only appliance installation with fixed connection is
permissible in wet areas.
Remove screws 1 and 2.
Pull off temperature selector switch.
Remove screw 3.
Lift off the housing cover.
Connect electrical cable 4 to terminal 5.
Replace the housing cover and screw it on.
VII.
Limiting the water temperature
Fig. 1: Insert the screwdriver into gap a and remove
cover b.
Fig. 2: Insert pin c into one of the 4 holes in order to limit
the temperature:
Hole C: ≈ 35 °C
Hole B: ≈ 45 °C
Hole A: ≈ 55 °C
Hole O: ≈ 75 °C
Fig. 3: Replace cover b.
Startup
Attention!
Fill the appliance with water before inserting the
mains plug or turning on the mains voltage!
Otherwise the temperature protection will trip and
has to be reset by a trained service professional.
VIII.
Flow rate setting DO15652
Rinse out the appliance by fully opening the hot water
tap.
Set the flow rate as per DIN 44531 or according to the
specifications of the fittings manufacturer:
max. flow rate: 10 l/min, i. e. the water flows out at a rate
of 1 litre in 6 seconds.
Set the flow rate by turning the screw valve on the upper
side of the mixer tap.
First heat-up
Turn the temperature selector switch to position “O”.
Switch on the fuses or insert the plug into the mains
socket.
Turn the temperature selector switch to position „III“.
Monitor the heating-up process (see „Technical Data“ for
heating times).
Check the temperature.
Turn the temperature selector switch to position „e“.
Hand over the installation and operating instructions to
the user and explain how the appliance operates.
Instruct the user regarding the necessity of regular
descaling.
Technical Data
DG15602
DO15652
Capacity
[l] 15.0
Rated output
[kW] 2
Rated voltage
[V] 230
Rated pressure
pressure-resistant operation [MPa (bar)] 0.6 (6)
unpressurised operation [MPa (bar)] 0 (0)
Weight
empty [kg] 11
filled [kg] 26
Heat-up time
from 12 °C to 60 °C [min] 25
from 12 °C to 75 °C [min] 75
Energy efficiency class
A
Hot water heating energy
efficiency
[%] 36.1
Load profile
XXS
Annual energy consumption
[kWh] 510
Daily energy consumption
[kWh] 2.391
Sound power level
[dB] 15
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens DO15652 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens DO15652 in the language / languages: English, German as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info