652210
14
Zoom out
Zoom in
Previous page
1/44
Next page
14
en
Operating instructions
Before using the appliance, please read the instruc-
tions carefully and observe them!
Important: The appliance may never be exposed to frost!
Risk of electric shock!
If a fault occurs, immediately disconnect the plug
from the power supply!
Immediately shut off the cold water supply to the
appliance should it leak.
Please read and observe the detailed safety instructions
at the start of these instructions!
VI.
Operation
The small water heater heats and stores drinking water up to
approx. 85 °C.
Setting the water temperature
The required outlet temperature from 35 °C to 85 °C can
be set with the rotary selector switch.
or:
Set the required fixed outlet temperature (A):
Frost protection
I Approx. 38 °C (soft lock-in)
e Conserve energy approx. 60 °C (soft lock-in)
III Hot water approx. 85 °C
The pilot lamp lights up during heat up.
Water drips out of the tap with oversink appliances.
The appliance with be covered more quickly with limescale
at higher temperatures.
Tip: Set the rotary selector switch to “e” to operate the appli-
ance economically and to reduce the effects of limescale.
Note: If the appliance has not been used for an extended
period, e. g. during a holiday, allow the water to briefly heat
up to stage “III”.
Limitation of the water temperature
Limit the outlet temperature to avoid scalding with hot water:
Set the rotary selector switch to ““.
Open the cover of the rotary selector switch.
Select between “I” = approx. 38 °C (B1) or “e” = approx.
60 °C (B2).
Close the cover.
Switching off
Set the rotary selector switch to ““ (A). The heating is
switched off.
Undersink appliances only DO05705M,
DO3170D5M and DO05705CHM
Drip stop
The drip stop function prevents expanding water from drip-
ping from the tap during heat up. If water is heated, the gas-
ses (air) dissolved in it will be released by the water.
Depending on the quantity of gas released – particularly
when a higher temperature is selected – it can force residual
water from the tap.
A
Pressure stop
The appliance features pressure switch off. The pressure
switch off indicates when the tap is clogged by limescale
(low or no flow). When water pressure exceeds 0.25 Mpa
(2.5 bar) it even detects if the appliance has been incorrectly
connected with the water line during initial installation.
The pressure switch off automatically shuts off the water
inlet and prevents rupturing of the tank.
It the pressure stop has tripped, a red pin will appear at the
top of the appliance (C1).
The fault must be corrected (see chapter “A fault,
what to do?”).
After the fault has been corrected, the red pin can be
pushed back in easily (C2). The water inlet is now free.
Please contact customer service if this occurs repeatedly.
Important: Do not block the path of the pin (C1) with objects.
Cleaning
Do not use aggressive or abrasive cleaning detergents!
Do not use a steam cleaner.
Clean appliance externally with a mild cleaning agent.
Clean the dirt and lime scale deposits in the aerator filter.
Descaling
Descale the outlet pipe with commercially available des-
caling agent or vinegar.
Please observe the manufacturers warnings when
descaling.
If the water flows significantly slower when the tap is fully
opened, the small water heater and tap should be descaled
by a specialist. Otherwise, the pressure stop may trip due to
an unpermissible high pressure.
Maintenance
The following repairs and maintenance may only be carried
out by an authorised customer service representative to
avoid potential sources of danger.
The electrical mains supply and the water supply must be
shut off before all work on the appliance.
Exchange of the electrical connection cable
When the electrical cable is visibly damaged:
Switch off the device, unplug the mains plug and contact
customer service.
B
Cleaning the inlet filter
When the flow of water is too low and the inlet filter in the
tap is descaled:
Contact customer service and get the inlet filter (D)
cleaned.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens DO05705M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens DO05705M in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 3,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info