652196
27
Zoom out
Zoom in
Previous page
1/32
Next page
19
Display (LED) Status
Cause / Fault
Solution Who
Heat content display
indicators (LED)
Anode Service
Fast Heating
On
On
On
On
On
On
On
Off
On
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Technician
Technician
Technician
Technician
Technician
Technician
Technician
Technician
Technician
Off
Off
Off
Off
Off
Off
Off
Off
Flashing
On
On
On
-
-
On
On
-
-
On
-
-
-
On
-
On
-
-
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
See
below
(*)
-
-
-
On
On
-
-
On
-
On
-
On
-
-
-
-
-
-
On
On
-
-
-
-
-
-
-
123456
Internal
electronic
failure
The reservoir
has heated
without water
Water
temperature
in reservoir
too hot
Internal
electronic
failure
Internal
electronic
failure
Temperature
sensor fault
Temperature
fault between
heating/sensor
Anode fault
Temperature
selector fault
Electronic board locked, wait 15mins and
then reset
Turn the device off, check the cause of the water
shortage (leakage, faulty water connection).
If the problem remains contact technician
Reset, wait until the reservoir has cooled.
If the problem remains please contact technician
Reset, if the problem remains please contact
technician
Reset, if the problem remains please contact
technician
Reset, if the problem remains please contact
technician
Reset, if the problem remains please contact
technician
Check that the reservoir is filled. If the problem
remains please contact technician
Reset not possible, please contact technician.
(*) the third LED indicates whether or not the off-peak contact was correctly installed.
Third LED “on” if off-peak contact on.
Third LED “offif off-peak contact out.
If the third LED is off during the off-peak period, the fault lies in the installation of the off-peak contacts.
When installing the device without off-peak contact, the third LED is always on.
Note
In an “error condition”, the device is out of order.
In the case of an “anode fault” or a “potentiometer fault”, the device can be manually activated for a heating cycle by press-
ing the “fast-heating” button . In this case the device heats until a water temperature of 40°C is reached. The device heats
at the installed power for single-power and boiler mode connections, for double-power connections it heats according to the
basic load of the connection, at 1kW, 2kW or 3kW.
If the fault could not be remedied, please contact the customer service operators.
Note
When the device is full with water and functions normally (there are no faults apparent), the device cannot be separated from
the mains voltage, otherwise the external power source anode stops functioning and the device rusts through. For complaints
of this nature, the warranty and guarantee do not apply.
After the assembly, please present the user with the instructions for use and explain the device to them.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens DG12025 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens DG12025 in the language / languages: English, German as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info