INSTRUCTION MANUAL OF THE SIEMENS CLIMATIX 2 CONTROL EQUIPMENT
-
12
-
B8 Flue gas temperature
O2 concentration
B4 Top buffer
B41 Bottom buffer
B1 Flow HC1
B12 Flow HC2
A6 Room HC1
A7 Room HC2
B3 DHW
B10 Cascade sensor
State of analog outputs (clicking on button F displays only information about the state of
outputs):
Fan
Return valve
Valve HC1
Valve HC2
Diagnostics of cascade (if it is used - clicking on button F displays only information about
the state):
B10 Cascade sensor
ON cascade
OFF cascade
Cascade power
Absolute cascade power
K1 diagnostics
Demand (demand active/no demand)
K2 diagnostics
Demand (demand active/no demand)
K3 diagnostics
Demand (demand active/no demand)
K4 diagnostics
Demand (demand active/no demand)
Sequencing priority
Actual sequencing
Actual time
Sequencing period
Time to change cascade priority
Diagnostics of source (clicking on button F displays only information about the state):
Diagnostics of boiler
- State of boiler
- Actual required temperature
- Temperature boiler ON
- Temperature boiler OFF
Diagnostics of buffer
- Buffer
- Top buffer B4 boiler ON
- Bottom buffer B41 boiler OFF
Demands from users
- HC1 demand
- HC2 demand
- DHW demand
12


Need help? Post your question in this forum.

Forumrules
1

Forum

siemens-climatix-2

Reset search

  • salve
    chiedo se è possibile fare un by pass per far partire il sistema di condizionamento a causa dell'oscuramento :del controllore POL/STD
    grazie
    Submitted on 11-3-2022 at 12:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Climatix 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Climatix 2 in the language / languages: English as an attachment in your email.

The manual is 1,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info