Step 7: Synchronization
Package contents Operation and storage
LL and INT mode are available for this camera. The
factory default is INT. User can change the setting to
Line lock mode in combination with an AC power
source by changing #3 pin of DIP SW (11) to LL.
Due to the physical nature of the CCD there is a
possibilty of picture noise when using the camera in
LL-mode under low-light conditions. Usage of
INT-mode is recommended.
CCD camera Do not operate or store the unit in following
locations: C/CS-mount adapter
Instruction manual Extremely hot or cold places
Close to sources of strong magnetism
Important
Close to sources of powerful electromagnetic
radiation such as radios or TV transmitters.
This quick start guide is only intended for use by
installers who have an adequate working knowledge
of video systems!
In humid or excessively dusty places
Where exposed to mechanical vibrations.
Step 8: SHARP/SOFT selection
Close to fluorescent lamps or objects reflecting
light.
Use DIP SW (11) pin 4 to select::
This guide outlines the most important information
about the camera. It is vital that you read this
manual carefully before any operation of camera.
Selection of picture sharpness (SHARP, SOFT).
Under unstable or flickering light sources
Step 9: Connecting power supply
Care and maintenance
Connect the power supply cable to the power
connectors (7) (see figure E):
Camera parts
The camera is maintenance-free.
See figure B, C, D and E
Use a clean soft piece of cloth to wipe small
amounts of dirt or dust from the camera body. If the
unit tends to get very dirty, the camera should be
placed within a protective housing.
Caution
1. Back focus adjust ring
If you are using a DC supply, make sure the
polarity is correct. Incorrect connection may
cause malfunction and/or damage to the
camera.
2. Back focus lock screw
3. Tripod mount hole
4. IRIS connector
5. Power indicator
Specifications
Select one of the following options
6. BNC connector for composite video output
Active pixels: 752(H) x 582(V)
7. Power cord (or terminal)
For 12 V DC:
Scanning system: 2:1 interlace CCIR
8. V-PHASE pot
Connect shielding to terminal GND (12).
Hor. Resolution: 580 TVL
9. LEVEL pot
Connect 12 V (-) to terminal =DC 12V- (13).
Min. Illumination: 0.15 Lux @F1.2
10. Video/ DC Lens selection
Connect 12 V (+) to terminal =DC 12V+ (14).
S/N-Ratio: > 50 dB
11. Mode setting switch
For 24 V AC:
Synchronisation: Internal or Line-Lock
12.
Connect 24 V (~) cables to terminals
~AC 24V (13 and 14).
Video Output: composite
Power requirement: DC 12V/AC 24V ±10% or
~AC90 – 260 V, 50 Hz
Installing the camera
Connect shielding to terminal GND (12).
Step 1: Mounting the camera
Power consumption: 3 VA
Adjusting camera settings
Camera weight: -LP: 450 g
1. Attach the camera to a wall bracket, ceiling
bracket, pan/tilt mount or other suitable fitting.
Use of the ¼ inch thread tripod mount hole (3) to
prevent the camera from rotating.
-MP: 550 g
Setting flange focal distance
Operating temperature: -10 ~ +50
Caution
Risk of damage to camera! Ensure that the locking
screw is loosened before turning the adjustment
screw. Avoid forcing the adjustment screw.
2. Mount the cable guide to the camera to ensure
that the cables are kept securely in place (see
figure A).
Fixed focus lenses
Step 2: Screw the lens onto the camera
1. Loosen the locking screw (2) by turning it
counter-clockwise.
Select one of the following options:
For C-mount lens: add a CS-C adapter to the
camera, then screw the lens directly onto the
camera.
2. Open the diaphragm to its fullest extent
manually. If the images are overexposed, or for
lenses with automatic diaphragm adjustment:
reduce lighting levels or hold a neutral grey filter
in front of the lens.
For CS-mount lens: Screw the lens directly
onto the camera (no adapter ring required).
Step 3: Connecting the lens
3. Set the focus to .
Two type of lens (DC or Video controlled) can be
used for this camera. However, please take note to
select DC or VIDEO lens using switch (10) before
connecting the lens and make sure the wire
connection for each type lens is conform to the pin
assignment below.
4. Point the camera at an object (at a distance of at
least 2000 times the focal length of the lens).
5. Adjust the backfocus ring (1), alter the flange
focal distance until the image is clearly in focus.
6. Re-tighten the locking screw (2).
Varifocal lenses
Then connect the control cable to the IRIS
connector (4, side or rear) on the camera.
Video Lens DC Lens
1. +12V 1. Damp-
2. NC 2. Damp+
3. VIDEO 3. Drive +
4. GND 4. Drive-
1. Loosen the locking screw (2) by turning it
counter-clockwise.
2. Open the diaphragm to its fullest extent
manually If the images are overexposed, or for
lenses with automatic diaphragm adjustment:
reduce lighting levels or hold a neutral grey filter
in front of the lens.
3. Set the focus to .
Step 4: Connecting video signal
4. Select the wide angle (min. focal length) setting.
For composite video: connect BNC connector
VIDEO OUT (6) to the monitor with a coax cable.
5. Point the camera at an object (at a distance of at
least 2000 times the focal length of the lens).
Step 5: Backlight compensation:
6. Adjust the backfocus ring (1), alter the flange
focal distance until the image is clearly in focus.
Backlight compensation is available by switching pin
1 of (11) to ON
7. Select the telescopic (max. focal length) setting
and adjust the focus to improve image clarity.
Step 6: AES/AI selection
8. Reset the camera to the minimum focal length
(wide angle) and fine adjust the flange focal
distance using the adjustment ring (1).
Use DIP SW (11) pin 2 to select:
Set to ON: AES (auto electronic shutter) mode
Set to OFF: AI mode (shutter speed=1/50 sec)
9. Re-tighten the locking screw (2).
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens CCBB1345 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens CCBB1345 in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info