521718
23
Zoom out
Zoom in
Previous page
1/73
Next page
22 Grondslagenhandboek AEROGYR™ RWI65.02 CM2Z3204H
3.3 Aansluitklemmen
G M
B1 B2 B4 B9 Z GE E1 E2 E3 E4 E5 E6 E7 E8
G0 Y10 G GY20 GY30 UP UN
AZI65...
F91 Q14 Q24 Q34 Q44
3204G01
Q13 Q33
G Bedrijfsspanning, AC 24 V, systeempotentiaal
G0 Bedrijfsspanning, systeemnul
M Meetnul (relatiepotentiaal van de gelijkspanning, identiek met G0)
B1 Meetsignaal van de ruimte- of afzuigluchttemperatuuropnemer
(LG-Ni1000 / DC 0...10 V)
B2 Meetsignaal van de inblaasluchttemperatuuropnemer
(LG-Ni1000 / DC 0...10 V)
B4 Meetsignaal van de buitentemperatuuropnemer
(LG-Ni1000 / DC 0...10 V)
B9 Meetsignaal van de vorstopnemer (LG-Ni1000 / DC 0...10 V)
Z Meetsignaal van de beïnvloedings opnemer (LG-Ni1000 / DC 0...10 V)
Y10 Uitgangssignaal DC 0...10 V voor verwarmen
Y20 Uitgangssignaal DC 0...10 V voor koelen
1)
Y30 Uitgangssignaal DC 0...10 V voor warmteterugwinning
GE Signaalspanningsnul voor digitale meldingangen
E1 Digitale meldingang “Brand”
E2 Digitale meldingang “Stromingsmelding”
E3 Digitale meldingang “Overbelaste circulatiepomp of elektrische
luchtverwarmer”
E4 Digitale meldingang “Overbelaste koelmachine”
E5 Digitale meldingang “Overbelaste ventilator”
E6 Digitale meldingang, vrij
E7 Digitale meldingang “besturingsingang 1”
E8 Digitale meldingang “besturingsingang 2”
F91 Verzamelstoringsmelding volgens storingsmeldtype (A en b, of A of b)
Q13/Q14 Potentiaalvrij relaiscontact, voor het schakelen van de circulatiepomp of de
elektrische luchtverwarmer
Q13/Q24 Potentiaalvrij relaiscontact voor compressor, DX-koeler of circulatiepomp
1)
Q33/Q34 Potentiaalvrij relaiscontact voor het schakelen van ventilatortrap 1
Q33/Q44 Potentiaalvrij relaiscontact voor het schakelen van ventilatortrap 2
UP, UN Aansluitingen (2...3) voor communicatie
Attentie: Opnemer LG-Ni1000 = L&S-norm
1) De besturingssignaaluitgangen Y20 en Q13/Q24 zijn gelijktijdig beschikbaar
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens AEROGYR RWI65.02 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens AEROGYR RWI65.02 in the language / languages: Dutch as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens AEROGYR RWI65.02

Siemens AEROGYR RWI65.02 User Manual - English - 20 pages

Siemens AEROGYR RWI65.02 User Manual - German - 50 pages

Siemens AEROGYR RWI65.02 User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info