The outdoor unit should be installed on a solid base. (Such as concrete) If it is in-
stalled against a brick wall, the thickness of the brick wall should be at least 10cm
deep. If there is a vibration, please install the protective anti-vibration rubber spacer.
Do not install the unit directly on the ground; the base has to be solid and resistant
enough to support the weight of the unit. It has to be firmly fixed. The unit should not
be installed on an angle greater than 5
0
.
When installing the unit, be sure to leave a space of 50 cm in front, more than 10 cm
behind, on top and on the left side of the unit and leave a space of 35 cm on the right
side.
3. Installation of Outdoor Unit
3-1 Flared Joint
You will have a flared joint on both units (indoor and outdoor). As indicated on the diagram, the
refrigerant pipe is used to connect the indoor unit and the outdoor unit.
Indoor unit
Outdoor unit
Refrigerant verification = If the length of the pipe is more than 5m, please refill the refrigerant
(fleon R410A).
Pipe length
less than 5m
more than 5m
need not to refill refrigerant
need to refill refrigerant 50g/m
One of the major causes for a gas leak is due to a defective flared joint, so please verify
the quality of the installation.
3-2 Pipe Joint
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Shinco KFR-50GWZ-BM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Shinco KFR-50GWZ-BM in the language / languages: English as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info