18
AUDIBLE ALARM
Alarms are listed on the next page.
When Reminder Alarm situations activate the Alarm, the unit will emit a quick double beep each second for 10 seconds, or
until the situation is corrected, or it is acknowledged by pressing the Advance (Front) button.
When Cautionary Alarm situations activate the Alarm, the beep will be on for 1/2 second then off 1/2 second, repeating for 10
seconds, or until the situation is corrected, or it is acknowledged by pressing the Advance (Front) button.
Some Alarms cannot be acknowledged. These are differentiated by 1 beep per second for 10 seconds followed by a full 3 sec-
ond beep.
If an Alarm is acknowledged and the situation corrected, the Alarm will sound again if the situation occurs again, or another
Alarm situation occurs.
A single short beep is emitted after the Diagnostic check, upon automatic return to Surface Mode from Simulator Mode, upon
completion of a fast battery change with calculations/settings saved, and upon change from Delayed to Full Violation after
that dive.
A red LED Warning Light located on the lower/left portion of the module is synchronized with the Audible Alarm and will
flash when the Alarm sounds. A scrolling message will also be displayed in the upper portion of the screen. The LED will
turn OFF when the Alarm is acknowledged or Set OFF, however, the message will continue to scroll until the condition is
cleared. In the event that another Alarm situation occurs, its scrolling message will be displayed until it is acknowledged, at
which time it will be replaced by the message that was previously scrolling.