Wisdom 3 DC Manual
© 2002 Design, 2011 Doc. No. 12-5274-r01 (8/31/11)
TIME
DESAT
AIR
TIME
DESAT
NITROX
FO2%
In addition to the DATA screens, you can use also use the front (Advance) button to access the -
• PLAN screens (sequence of allowed dive depths/times )
• LAST screen (previous dive's data)
• LOG screens
• HISTORY screen
• SIMULATOR Mode
• SET Modes
FLY/DESAT appears automatically 2 hours after a dive. Desat time also appears on DATA displays.
DATA SCREENS
The DATA screens are accessible during a new activation period or greater than 10 minutes after surfacing
from a dive. By pressing the front (Advance) button 1 time while the TIME (or WET) screen is being dis-
played (TIME/WET > DATA), you can access the DATA screen representing the Mode that you set the dive
computer to operate in (Nitrox, Air, or Gauge described later).
You can also access the DATA screen when FLY/SAT is being displayed during the period from 2 hours to 24
hours after a dive pressing the front (Advance) button 1 time to rst recall the TIME/WET screen from which
you can access to the sequence of Surface Displays.
FLY/SAT > TIME/WET > DATA > PLAN > LAST > LOG > HISTORY > SIMULATOR > SET
ALTITUDE LEVEL Graphics that appear on DATA or Log/History screens represent the following -
SEA = 0 to 3,000 feet (915 meters)
LEV2 = 3,001 to 5,000 feet (916 to 1,525 meters)
LEV3 = 5,001 to 7,000 feet (1,526 to 2,135 meters)
LEV4 = 7,001 to 9,000 feet (2,136 to 2,745 meters)
LEV5 = 9,001 to 11,000 feet (2,746 to 3,355 meters)
LEV6 = 11,001 to 13,000 feet (3,356 to 3,965 meters)
LEV7 = 13,001 to 14,000 feet (3,966 to 4,270 meters)
outr = > 14,000 feet (> 4,270 meters)
AIR MODE DATA screen (Fig. 14)
Alpha graphic DATA
Alarm icon (if all alarms set On)
• Temperature and graphic (F or C)
• DeSat time and graphic, if any
AIR graphic (indicating operating mode)
Altitude level graphic if > Sea level as LEV2 (through LEV7), or outr (out of range)
NITROX MODE DATA screen (Fig. 15)
Alpha graphic DATA
Alarm icon (if all alarms set On)
• Temperature and graphic (F or C)
• DeSat time and graphic, if any
• NITROX graphic (indicating operating mode)
• PO2 and FO2 set points, and FO2 graphic
Altitude level graphic if > Sea level as LEV2 (through LEV7), or outr (out of range)
While viewing the AIR or NITROX DATA screen -
• Pressing Both buttons for < 2 seconds activates the Backlight.
• Pressing Both buttons for => 2 seconds reverts to the TIME/WET screen.
• Pressing the front (Advance) button accesses the PLAN screen.
The unit reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
Fig. 14 - Air Mode Data
Fig. 15 - Nitrox Mode
Data
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sherwood Wisdom 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sherwood Wisdom 3 in the language / languages: English as an attachment in your email.

The manual is 8,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info