Clerk assignment
Prior to any item entries, clerks must enter their clerk codes into the register. However, the code entry may not
be necessary when the same clerk handles consecutive transactions.
Receipt ON/OFF function
You can disable receipt printing in the REG mode to save paper using the receipt ON/OFF function. To disable
receipt printing, press the
R
key in the OP X/Z position. This key toggles the receipt printing status ON and
OFF.
To check the receipt printing status, turn the mode switch to the OP X/Z position or press the
l
key in the REG
mode. When the function is in the OFF mode, the receipt off indicator “_” illuminates.
The register will print reports regardless of the receipt state, so the paper roll must be installed.
To issue a receipt when receipt ON/OFF function is set to OFF:
If your customer wants a receipt after you finalized a transaction with the receipt ON/OFF function in the OFF
mode, press the
R
key. This will produce a receipt. If more than 50 items were entered, the receipt will be
issued in a summary receipt format. Your register can also print a copy receipt when the receipt ON/OFF
function is in the “ON” status.
Power Save Mode
The register will enter into power save mode when no entries are performed based on the pre-programmed time
limit (by default, 30 minutes).
When the register goes to the power save mode, all display lights will turn off except the decimal point at the
leftmost position of the lower line. The register will return to normal operation mode when any key is pressed or
a mode is changed with the mode key. Please note when the register is recovered by a key entry, its key entry
is invalid. After the recovery, start the key entry from the beginning.
K
Clerk code 1 to 40
To display the signed-on clerk code
KK
Sign-on (in REG, MGR, VOID mode) Sign-off (in REG, MGR, VOID mode)
In the following examples, your register will go into an error state accompanied with a warning beep and a
corresponding error message. Clear the error state by pressing the
l
key and take proper action.
Please refer to the error message table on page 79.
• Enter over a 32-digit number (entry limit overflow): Cancel the entry and re-enter the correct number.
• An error in key operation: Clear the error and continue operation.
• An entry beyond a programmed amount entry limit: Check to see if the entered amount is correct. If it is
correct, it can be rung up in the MGR mode. Contact your manager.
• An including-tax subtotal exceeds eight digits: Delete the subtotal by pressing the
l
key and press the
A
,
C
,
X
or
Y
key to finalize the transaction.
Error escape function
To quit a transaction due to an error or an unforeseen event, use the error escape function as shown below:
The transaction is voided (treated as a subtotal void) and the receipt is issued by this function. If you have
already entered a tendered amount, the operation is finalized as a cash sale.
l
Transaction
To clear the error state
E
E
Error Warning
2
A505_2 FOR THE OPERATOR 06.6.26 4:02 PM Page 14
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp xe a505 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp xe a505 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info