Description of misoperation
The following two types of misoperation disposal are possible:
Type 1: Misoperation in the case when there is established clerk code which has been defined by the
POS terminal based on the clerk code inputted from the drink dispenser and the PLU assigned by
using the sort number of drink dispenser sales, but the GLU code is wrong. (The GLU code is out
of the range for the clerk or has already been used by another clerk.)
Such a misoperation is recorded in the drink dispenser misoperation file. At this time the following
data is updated:
• Totalizer for the associated department
• Totalizer for each PLU
• Stock counter (if controlled)
(Data of pertinent clerk)
• Order total
• Commission sales amount
• Non-commission sales amount
Type 2: Fatal error in the case when the clerk code and PLU code of information (clerk code, sort
number) sent from the drink dispenser cannot be identified and the totalizers for clerk or PLUs
cannot be updated.
Such an error is recorded in the drink dispenser misoperation file without updating of totalizers.
Accordingly, these errors are not registered in the POS terminal. They are recorded only in the
drink dispenser misoperation file. These errors cannot be corrected with the correction operation.
These errors are roughly classified into the following two groups :
• Errors which make it impossible to identify the PLU code.
• Errors which make it impossible to identify the clerk code.
The former error is printed out with correction disabled mark when reading the drink dispenser
misoperation or reading the drink dispenser misoperation of clerk report. If the clerk code cannot
be identified, the error cannot be read by drink dispenser misoperation read operation but read/
reset is possible in the X/Z mode. However, if the clerk code corresponding to the clerk code is
defined in the POS terminal system after occurrence of error whose clerk code cannot be
identified, it cannot be corrected with the correction operation. Accordingly, it is printed out as
drink dispenser error read list, being distinguished from the ordinary misoperation read.
Misoperation file reading
Each clerk can display out only his/her misoperation data in the misoperation file in the REG or MGR mode.
Procedure
Select “MOP READ”
from the window
(REG or MGR mode)
MISC FUNCTIONS
ENTER
NOTE
The data of the drink dispenser misoperation file can be printed or displayed out as well in the OP X/Z and
X1/Z1 modes.
UP33_10.p65 3/22/99, 12:05 PM237
237


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp UP3300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp UP3300 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info