787900
7
Zoom out
Zoom in
Previous page
1/46
Next page
EN
Memory function
1. If the unit is turned o via the POWER button, when turned back on
again it will resume from the function it was turned o in. Note that if
the timer was set or if the unit was in the lock mode, these settings are
not stored.
2. If the mains power is disconnected while the unit is operating, it will
not start automatically when the mains is reconnected. When the mains
power is applied again, you will need to press the POWER button to
restart operation. The unit will start up in the initial mode.
Water tank full auto-stop function
When the water tank is full, the unit will stop operation, the air outlet
louver will close and a buzzer will sound. To reset, remove the water tank,
empty and replace. When the empty water tank is put back into the unit, it
will restart. Note that the compressor will take about 3 minutes to operate.
Auto defrost
If the unit is used in a low temperature environment, the internal
evaporator may be covered by frost. In order to make sure the machine
operates normally, the machine has auto-defrost function. Should
the internal sensor detect a temperature of ≤-1°C the machine will
enter auto-defrost function. That means it will run continuously in the
dehumidication mode for 30 minutes, then the machine will start the
defrost cycle, the DEFROST light will illuminate, the compressor will stop
and that fan will operate at high speed.
When temperature of evaporator is ≥2°C and the unit has been in the
defrost mode for 10 minutes, the auto-defrost mode will turn o and the
compressor turns on. At this point the unit will start to dehumidify and the
DEFROST light will turn o.
While in the defrost mode and the temperature of the evaporator is ≥0°C
for two minutes, the defrost function is cancelled.
Compressor protection function
Should there be a problem with the unit causing the compressor to stop,
the compressor will turn o for 3 minutes. Normally the compressor will
restart after 3 minutes, if it does not unplug the unit for an hour and try
again. If it still does not start, call for service.
High/Low temperature protection
function
If the unit detects that the ambient temperature is outside of the normal
operating range of 5°C to 38°C, it will shut down. When the normal
operating range is reached, the compressor will start. Note that it will take
the compressor 3 minutes to start working once the normal temperature
range is met.
Low humidity protection function
If the unit detects low humidity of <30% the display will indicate LO and
it will stop any dehumidifying action and the fan will operate a the lowest
speed.
If the humidity is over 80%, the display will indicate HI and keep
dehumidifying.
High temperature fan speed switch
function
When the unit is dehumidifying in a high temperature environment and
the fan speed is set to low, it will switch automatically to the high speed.
This is to prevent excessive load on the compressor. When the ambient air
temperature reduces, the fan speed will return to the low setting.
Error codes
There are number of error codes which may appear in the display, these are
as below. When the error code is displayed, it will ash. If any of these error
codes are experienced, call for service.
C1 – Indicates that there is a fault with the evaporator temperature sensor.
In this condition, the unit will stop working.
C2 – Indicates that there is a fault with the ambient air temperature sensor.
In this condition, the unit will stop working.
C8 – The temperature of the evaporator checked every 8 minutes, if this is
within ≤3°C of the ambient air temperature for 5 consecutive checks, the
unit will shut down and the error code C8 is displayed.
Continuous drainage function
Should it be necessary to provide continuous drainage, this can be
achieved by tting a 15mm inner diameter pipe to the drainage hole on
the rear of the unit. When installed, water will drain through the pipe and
not into the water tank.
Ensure that the drainage pipe runs in a downwards direction, and it not
bent or damaged in any way so that the water runs freely out of the unit.
When tting the drainage pipe, make sure that it is pushed all the way into
the drainage hole so that it pushed over the drain outlet which is located
about 70mm inside the unit from the rear cover of the unit.
Refer to the 3 on page 1 for the location of the drainpipe connection port.
Maintenance
When cleaning your dehumidier:
Use a soft clean cloth.
Do not use the alcohol, gasoline, and other benzene chemical solvents.
To clean the lter, remove it, then use a vacuum cleaner to clear any dust
which may have built up. If necessary, use water to clean, then place it in
ventilated area until dry.
Unplug the unit from the mains supply before cleaning.
Other advice:
Before moving the unit, unplug the mains supply and pull out the water
in tank.
If not using the unit for a long time, unplug the unit from the mains sup-
ply, empty the water tank, wait for 2 days to make sure the unit inside
completely dry before packing.
Always store the unit in an upright position.
Do not tilt the unit horizontally or turn upside down.
If the unit requires repair, seek help of a professional person.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp UD-P20E-W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp UD-P20E-W in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 2.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info