TROUBLESHOOTING
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not
removed.
Clean or replace the fi lters if they appear to be heavily soiled.
(Ref. E-8,E-9)
The DUST SIGN illuminates green
even when the air is impure.
The air could be impure at the time the unit was plugged in.
Unplug the unit, wait one minute, and plug the unit in again.
The DUST SIGN illuminates orange
or red even when the air is clean.
Sensor operation is aff ected if the dust sensor fi lter is dirty or
clogged. Gently clean the dust sensor fi lter. (Ref. E-9).
A clicking or ticking sound is heard
from the unit.
Clicking or ticking sounds may be audible when the unit is
generating ions.
The discharged air has an odour.
Check to see if the fi lters are heavily soiled.
Clean or replace the fi lters.
Plasmacluster Air Purifi ers emit small traces of ozone which may
produce an odour. These ozone emissions are well below safety
level.
The unit does not operate properly
when cigarette smoke is in the air.
Is the unit installed in a location that is diffi cult for the sensor to
detect cigarette smoke?
Is the dust sensor fi lter blocked or clogged?
(In this case, clean the fi lter.) (Ref. E-9)
The
DUST SIGN
is turned off .
Check to see if the Lights OFF Mode is selected.
Press
for 3 seconds to turn light ON.
(Ref. E-7)
Check to see if the SLEEP mode is selected.
The DUST/PLASMACLUSTER SIGN are turned off automatically
after the SLEEP mode is selected.
The DUST SIGN changes colour
frequently.
The DUST SIGN automatically changes colours as impurities
are detected by the dust sensor.
The sensor detection sensitivity can be adjusted lower.
(Ref.E-7)
Before calling for service, please review the Troubleshooting list below, since the problem may not
be a unit malfunction.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp UA-PF40E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp UA-PF40E in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 5,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info