54
Maintenance Indicators (Continued)
Maintenance indicator
Problem Cause Possible Solution
Normal Abnormal
Temperature
warning
indicator
Off Red blinks
(On)/
Red on
(Standby)
The internal
temperature is
abnormally high.
Temperatures
around the projector
are high.
Blocked air intake
Use the projector in an
area with a temperature of
lower than 95°F (+35ºC).
Relocate the projector to
an area with proper
ventilation. (See page
8.)
Cooling fan
breakdown
Internal circuit failure
Clogged air intake
Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page
61) for
repair.
Lamp
indicator
Green on
(Green
blinks
when the
lamp is
warming
up.)
Red on The lamp does
not illuminate.
The lamp is shut
down abnormally.
Disconnect the power cord
from the AC outlet, and
then connect it again.
Time to change
the lamp.
Remaining lamp life
becomes 5% or less.
Carefully replace the lamp.
(See page
55.)
Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page
61) for
repair.
Please exercise care when
replacing the lamp.
Securely install the cover.
Red on
(Standby)
The lamp does
not illuminate.
Burnt-out lamp
Lamp circuit failure
Power
indicator
Green on/
Red on
Green
blinks
(Cooling)
Red blinks The power
indicator blinks in
red when the
projector is on.
The lamp unit cover
is open.
If the power indicator blinks
in red even when the lamp
unit cover are securely
installed, contact your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page
61) for
advice.
Info
If the temperature warning indicator illuminates, and the projector enters standby mode, follow the
possible solutions above and then wait until the projector has cooled down completely before
plugging in the power cord and turning the power back on. (At least 10 minutes.)
If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the lamp indicator will illuminate
in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace
the power cord in the AC outlet and then turn the power on again.
The cooling fan keeps the internal temperature of the projector constant and this function is
controlled automatically. The sound of the cooling fan may change during operation because the fan
speed may change and this is not a malfunction.
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp PG-D40W3D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp PG-D40W3D in the language / languages: English as an attachment in your email.

The manual is 10,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sharp PG-D40W3D

Sharp PG-D40W3D User Manual - German - 35 pages

Sharp PG-D40W3D Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info