564779
214
Zoom out
Zoom in
Previous page
1/226
Next page
214
Setting the date and time when the automatic EURO modi cation operation should be executed
To certainly execute the automatic modi cation operation, you can program the scheduled date and time to
execute the automatic EURO modi cation operation. From two days before the preset date, the remaining
days are printed at the bottom of the daily full resetting report.
Date and time setting will be reset after the execution of automatic modi cation operation, and again you
can program the date and time for the next automatic modi cation operation.
Also you can make the automatic EURO modi cation operation compulsory. When the above-mentioned
preset date and time has come, and also when you start an entry in the REG/MGR mode, the error message
“EURO CHANGE ENTRY COMPULSORY” will be displayed. You cannot start any operation in the REG/
MGR mode until you make the operation.
Automatic EURO modi cation operation
1. Select “4 X2/Z2 MODE”.
2. Select “3 EURO STATUS” from the menu.
3.
Select the status you want to set (B, C or D) referring to the table on the previous page. Press the
P
key to toggle the options.
Please note that once you set a status, you cannot return to the previous status(es).
Important note
As for the miscellaneous keys, such as
-
and
¡
keys, and for the HALO setting, the automatic
conversion will not be made. You need to change the % rates or amounts in the PGM mode after the
execution of the automatic modi cation operation for EURO so that they are based on amounts in
EURO.
It is executed some of following operation which is needed for each status.
NOTE
1) Issue General Z1 report. 2) Issue General Z2 report. 3) Clear GT1/2/3 and Training GT. 4)
Convert the unit price of departments/PLUs/EANs from LOCAL currency to EURO. If new unit
price is over the max digits, its price is set as "0.00". 5) Change PGM function “EX1 amount
printing for total and change YES/NO”. 6) Change PGM function “EX1 calculation method
DIVISION/MULTIPLICATION”. 7) Set “EX1 currency symbol” as the suitable data. 8) Set “EX1
TAB” as the suitable data. 9) Set “Domestic currency symbol” as EURO SYMBOL. 10) Set
“Domestic TAB” as “2”. 11) Set “Rounding SYSTEM (Denmark/Sweden/Normal)” as “Normal”.
12) Set “Rounding up/down of the unit digits of AMOUNT” as “No”. 13) Set “Lowest digit entering
limitation of item” as “Arbitrary”. 14) Set “Lowest digit entering limitation of payment” as “Arbitrary”.
15) Set “Difference memory” as “No”. 16) Set “Rounding of foreign currency for EX” as “Round
off(4-DOWN,5-UP)”. (EURO Regulation)
NOTE
This job cannot set the following additional EURO function. You must set the following items by
each programming after executing the automatic EURO modi cation operation.
1) Exchange1 rate, (2) “Check, Credit operation for Exchange1 — YES/NO”
214


Need help? Post your question in this forum.

Forumrules
1

Forum

sharp-er-a411

Reset search

  • The Till Sharp er-a411 is logged, doesn't want to open, how to open it? Submitted on 16-2-2023 at 13:11

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp ER-A411 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp ER-A411 in the language / languages: English as an attachment in your email.

The manual is 9,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sharp ER-A411

Sharp ER-A411 User Manual - English - 4 pages

Sharp ER-A411 Quick start guide - German - 4 pages

Sharp ER-A411 User Manual - German - 226 pages

Sharp ER-A411 Quick start guide - Dutch - 4 pages

Sharp ER-A411 User Manual - Dutch - 226 pages

Sharp ER-A411 User Manual - French - 226 pages

Sharp ER-A411 User Manual - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info