DRUM CARTRIDGE REPLACEMENT
AUSWECHSELN DER TROMMELEINHEIT
The useful life of the drum cartridge is approximately
18,000 copies. When the internal counter reaches
approximately 17,000 copies, the drum replacement
required (
w
) indicator will light up indicating that
replacement of the drum cartridge will be needed soon.
For more information on purchasing the drum cartridge,
see SUPPLY PART NUMBERS AND STORAGE on
page 1-36. When the indicator begins to blink, the copier
will stop operating until the cartridge is replaced.
Replace the drum cartridge at this time.
Do not remove the protective cover
on the drum portion (black paper)
of a new drum cartridge before use.
The cover protects the drum against
external light.
1. Ensure that the bypass tray (AL-1551
only) is open and then open the side
cover while pressing the side cover
open button.
2. Gently pull the TD cartridge out whilst
pressing the lock button. To remove the
TD cartridge, see page 1-23, step 2.
3. Hold the handle of the drum cartridge
and gently pull the cartridge out. Dis-
pose of the old drum cartridge in ac-
cordance with local regulations.
4. Remove the new drum cartridge from
the protective bag and remove the
protective cover from the cartridge.
Then gently install the new drum car-
tridge.
Do not touch the surface of the
drum (green portion) of the car-
tridge. Doing so may cause smudg-
es on the copies.
Die Lebensdauer der Trommeleinheit beläuft sich auf ca.
18000 Kopien. Wenn der interne Zähler etwa 17000 Kopien
erreicht, leuchtet die Anzeige für den erforderlichen Aus-
tausch der Trommeleinheit (
w
) auf. Sie weist darauf hin,
daß in Kürze ein Auswechseln der Trommeleinheit erfor-
derlich sein wird. Weitere Hinweise zum Kauf der Entwick-
lereinheit finden Sie auf Seite 1-37 im Abschnitt AUFBE-
WAHRUNG UND ARTIKELNUMMERN VON ZUBEHÖR
UND VERBRAUCHSMATERIALIEN. Wenn die Anzeige
zu blinken beginnt, stellt der Kopierer den Betrieb ein, bis
die Trommeleinheit ausgewechselt ist. In diesem Fall die
Trommeleinheit auswechseln.
Die Schutzabdeckung des Trommel-
teils (schwarzes Papier) nicht vor
Verwendung der neuen Trommelein-
heit entfernen. Die Abdeckung
schützt die Trommel vor Lichteinwir-
kung.
1. Darauf achten, daß das Fach für Mehr-
facheinzug (nur AL-1551) geöffnet ist.
Die Verriegelungstaste der Seitenab-
deckung drücken und die Seitenabdek-
kung gleichzeitig öffnen.
2. Den Entriegelungsknopf der Entwick-
lereinheit drücken und gleichzeitig die
Entwicklereinheit vorsichtig heraus-
ziehen. Zum Entnehmen der Entwick-
lereinheit siehe Seite 1-23, Schritt 2.
3. Den Griff der Trommeleinheit fassen
und die Trommeleinheit vorsichtig
herausziehen. Die verbrauchte Trom-
meleinheit gemäß den örtlichen Vor-
schriften entsorgen.
4. Die neue Trommeleinheit aus der
Schutzhülle nehmen und die Schutz-
abdeckung entfernen. Die neue Trom-
meleinheit anschließend vorsichtig
installieren.
Die Trommeloberfläche (grüner
Teil) der Trommeleinheit darf nicht
berührt werden. Andernfalls werden
die Kopien unsauber.
Then, push gently on both sides of the
front cover to open the cover.
Dann vorsichtig an beiden Seiten der
Frontabdeckung drücken, um sie zu
öffnen.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp AL-1452 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp AL-1452 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info