(1)
Valve cap
(
2) Valve
insert
(
3) Valve
base
K330R
(NA) 2 adults 165 kg / 364 lbs (NA)
K79
U235YEL 2 adults 155 kg / 342 lbs 400 lbs / 180kg
K79HF
U235GRN 2 adults 155 kg / 342 lbs 400 lbs / 180kg
K79SB
U235ORG 2 adults (NA) 400 lbs / 180kg
K109HF
(NA) 2 adults, 1 child 200 kg / 441 lbs (NA)
ASSEMBLY INSTRUCTIONS / INFLATION
CAUTION !
Do not use sharp tools !
When inflating for the first time, inflate indoors at room temperature the PVC will be soft and assembly will be easier. If
the item was stored below 0°C, leave it at 20°C for 12 hours before unfolding. Inflate it with an inflator from Sevylor or any
inflator designed for inflatable boats, rafts, pool floats, air beds, camping mattresses, and other low pressure inflatables.
These types of inflators have a hose and adaptors to fit the valves on this product.
CAUTION !
Using of an air compressor will damage your product and automatically void all warranties.
Choose a smooth and clean surface on which to unfold your product.
1. Your kayak is equipped with two different types of valves:
a) Boston valve(s) please see opposite figure : Unscrew the valve cap (1). Screw
the valve insert (2) onto its base (3) and check that the valve cap stays accessible.
Insert the pump hose end piece and inflate it until you will reach the required
pressure (see point 3). After inflation fit all the valve(s) cap tightly (clockwise).
NOTICE: A slight air-leak before screwing the valve(s) cap is normal. Only the
valve(s) cap can ensure final AIR TIGHTNESS.
b) Push-in valve(s) : open the cap of the valve and inflate it using the adaptor of the
inflator which fits the valve. Close the valve and press it into the air chamber.
2. Inflate the kayak in the order of inflation as shown on the capacity plate printed on the product (see also figure # 1 -
numbering of the valves).
3. Max. air pressure : The correct pressure for this item is : 0.06 bar (= 60 mBar / 0.9 PSI). Do not exceed it. Your
kayak features a SEVYTEST pressure indicator which indicates the proper pressure : If the ambient temperature is
rather cool, inflate the side chambers until “A” marking on the Sevytest ; if the ambient temperature is elevated, inflate
until “B” marking. Overpressure: deflate until you reach the recommended pressure. Drop of pressure: inflate again
slightly. NOTICE : PVC material extending under the inflation pressure, after many inflations the Sevytest gauge may
not return to its initial position but it still will allow you to check that the gauge remains within the recommended zone.
4. Seats installation: place the inflated seats (if removable) into the kayak.
WARNING !
If you leave your product exposed to the hot sun check the pressure and deflate it slightly, to avoid
overstretching the material.
The ambient temperature affects the tube’s internal pressure : a variation of 1°C (1.8°F) causes a variation of the
pressure in the tube of +/- 4 mBar (0.06 PSI).
OPERATING INSTRUCTIONS
WARNING !
Use the kayak only in protected shore-zones, avoid open water and streams with strong currents.
BEWARE OF OFFSHORE WINDS AND CURRENTS !
Observe local regulations and hazards related to this sport or water activities.
Before using the kayak, please check it carefully.
Be careful that you do not over estimate your strength, your endurance or your skill.
Don’t use this item under the influence of alcohol or drugs.
Do not exceed the maximum number of persons or weight.
Avoid all contact between the buoyancy tubes and sharp objects or aggressive liquids (such as acid).
This kayak is equipped with ropes. Keep the ropes away from children.
Some kayak models are delivered with a carry bag. Keep it away from children. Danger of suffocation!
E
N
G
L
I
S
H
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sevylor FIGI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sevylor FIGI in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info