connected to the mains.
When the unit is rst switched on, a slight ‘new’ smell may
be noticed. However, this will disappear once the cooling
process has begun.
Installation
The appliance should be set up in a well-ventilated, dry room.
It should be operated in conditions where the relative humidity
is no more than 70 %.
The product data sheet contains details of the ambient
temperature range suitable for this appliance.
Do not use the appliance outdoors.
Ensure that the plug is accessible and can be removed from the
wall socket at any time.
Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers etc). If
this cannot be avoided, however, suitable insulation must be in
installed between the heat source and the unit.
The unit must not be installed inside a cabinet, nor directly
below a hanging cupboard, shelf or similar object.
Ensure that the door can swing open to an angle of 90°.
If the oor is uneven, the adjustable feet on the unit can be
used to compensate and ensure optimum stability.
Ventilation
The heated air around the unit must be able to circulate freely.
Therefore, ensure that the circulation around and above the
unit is not obstructed.
The clearance must be at least 150 mm.
Temperature control
The unit is activated by connecting it to the mains. It is only
switched off completely when the plug is removed from the
wall socket.
The temperature in the refrigerator cabinet can be adjusted
by setting the temperature control (1-7). Turning the control
clockwise will decrease the temperature, while turning it anti-
clockwise will increase it.
The temperature can be set within a 5 to 18°C range.
The temperature in the cabinet largely depends on factors
such as the ambient temperature, the setting and the
number of wine bottles stored.
We recommend using a thermometer to check the actual
temperature inside the cabinet and make adjustments as
necessary.
Always ensure that the door is properly closed and that the
seal is not obstructed by bottles stored inside the cabinet.
Following a power interruption, or if the unit has been
switched off on purpose, it may take 3 to 5 minutes before it
switches on again.
Note: In position ‘0’, the cooling function is switched
off, though the appliance is still connected to the mains.
Interior lighting
The interior light can be switched on by means of the
separate On/Off switch.
Caution: do not remove the cover of the interior LED
light. If there should be any malfunction, please contact the
customer service for assistance.
Storing wine
The following temperatures are suitable for various wines:
Red: 15 -18°C
Dry/white: 10 -15°C
Sparkling/champagne: 5 - 9°C
De-frosting and cleaning
During operation, you may notice a build-up of frost around
the integral evaporator sealed into the rear of the inside
cabinet. This layer of frost will start melting when the
compressor is not working. Through a system of hoses,
the melt-water drains into the collection tray below the
compressor, where it will be absorbed into the surrounding
air.
The unit does not therefore require de-frosting, but only
proper cleaning.
To enable the melt-water to drain freely, always ensure that
the channel and discharge opening in the cabinet are free of
any blockage.
Any water collecting in the bottom should be removed.
Remark: Do not use abrasive tools, materials containing
alcohol or harsh cleaning solutions. Do not use any electrical
appliances, such as steam cleaners, for de-frosting or
cleaning.
Always remove the plug from the wall socket before
cleaning.
Do not pour water over or inside the unit.
For frequent cleaning we recommend the use of warm water
with some mild detergent.
The cabinet should be cleaned once a month.
Any accessories should be cleaned separately with soapy
water. Do not put them in a dishwasher.
After cleaning, thoroughly clean all surfaces with fresh water
before wiping them completely dry. When re-inserting the plug
into the wall socket ensure that you have dry hands.
To save energy and to ensure optimum performance, the
compressor (at the rear) should be carefully cleaned at least
twice a year, with a brush or a vacuum cleaner.
Trouble-shooting
Certain typical sounds can be heard when the appliance is
switched on. These sounds are caused by:
the electric motor
within the compressor
assembly; during
compressor start-up
the sound level will be
slightly higher for a
short time.
the cooling agent
owing through the circuit.
In addition, the side of the housing may become warm. This
heat is caused by dissipation of the heat generated inside
the cabinet.
The following table lists possible malfunctions, their probable
causes and solutions. In the event of operational problems,
check rst whether a solution can be found using this table. If
the problem persists, disconnect the appliance from the mains
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Severin KS 9894 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Severin KS 9894 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Severin KS 9894

Severin KS 9894 User Manual - English - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info