753073
24
Zoom out
Zoom in
Previous page
1/562
Next page
Installation instructions, for professionals only p. 24/70
4.4. Installing bench sensor F2 (optional)
The bench sensor must be installed on the wall of the sauna room, above the
rear bench seat. A clearance of approx. 15 cm from the roof of the sauna room
must be maintained.
To install the bench sensor, perform the following steps:
1. Route the two 2-core bench sensor leads in the wall of the sauna room to
thebenchsensorinstallationlocationanda󰀩xthebenchsensorleadsus-
ing cable clips.
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor lead to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna room using the two wood
screws enclosed (16 mm). Maintain a clearance of 15 cm from the roof of
the sauna room.
4.5. Installing humidity sensor FTS2
(optional, only Pro D3/Pro D3i)
The humidity temperature sensor must be installed on the wall of the sauna
room above the rear bench seat. A distance of approx. 15 cm from the roof of
the sauna must be maintained.
To install the humidity temperature sensor, perform the following steps:
1. Route the two 5-core bench sensor leads in the wall of the sauna room to
thehumiditytemperaturesensorinstallationlocationanda󰀩xthesensor
leads using cable clips.
2. Install the humidity temperature sensor to the wall of the sauna room using
the two wood screws enclosed (16 mm). Maintain a clearance of 15 cm from
the roof of the sauna room.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sentiotec Pro D2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sentiotec Pro D2 in the language / languages: English, German, Dutch, French, Italian, Swedish, Finnish as an attachment in your email.

The manual is 15,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info