753070
12
Zoom out
Zoom in
Previous page
1/268
Next page
Installation instructions, only for experts p. 12/38
4. Installation
4.1. Installing the sauna control unit
Observe the following points when installing the sauna control unit:
The sauna control unit must be installed outside the sauna room or in accord-
ance with the recommendation issued by the sauna manufacturer.
The ambient temperature must be within a range spanning -10 °C to +40 °C.
The sensors may only be connected using the sensor wires provided with the
unit, which are heat-resistant up to 150 °C.
ATTENTION!
Damage to the unit
The sauna control unit is protected against jets of water, however direct contact
with water could still damage the unit.
Install the sauna control unit in a dry place at which a maximum humidity of
95 % is not exceeded.
The sensor wires may be extended under the following conditions:
When a silicon wire resistant to temperatures up to 150 °C is used.
The minimum cross-section of the wire is 0.5 mm2.
The length of the heater sensor wires may NOT exceed 10 m.
ATTENTION!
Sources of interference can have a negative eect on signal transmission
Lay all sensor wires separately from other mains wires and control wires.
Protect wires with only one layer of insulation by using a pipe (double insulation).
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sentiotec Pro B3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sentiotec Pro B3 in the language / languages: English, German, Dutch, French, Italian, Swedish, Finnish as an attachment in your email.

The manual is 11,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info