Bit #
Error code
Error description
Suggested action
0
CO
2
sensor
Com. error
No ability to communicate
with CO2 sensor module.
Try to restart sensor by
power OFF - power ON.
Contact local distributor.
1
CO
2
sensor
CO
2
measure error
CO
2
measurement error.
Try Background calibration
(“Calibration options CO
2
” p.16).
Contact local distributor.
See Note 1!
2
T sensor
T measure error
Temp measurement error.
Try to restart sensor by
power OFF - power ON.
Contact local distributor.
3
RH/T sensor
com error
No ability to communicate
with RH/T sensor module.
4
RH/T sensor
RH measure error
RH measurement error.
5
RH/T sensor
T measure error
Temp measurement error,
sensor will use CO
2
sensor
temperature if RH/T
Temperature is unavailable.
S_Temp will be set to
NTC_Temp.
6
7
8
Output config.
error
Error in output configuration.
Output is still updated,
i.e. can be 0-10V
Check connections and loads of
outputs.
Check detailed settings and
configuration with UIP software version
5 or higher.
Contact local distributor.
9
Memory error
One or several bytes of
sensors parameter memory
(settings) are corrupt
Try to restart sensor by power OFF/ON
Contact local distributor.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair tSENSE Disp at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair tSENSE Disp in the language / languages: English as an attachment in your email.

The manual is 3,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Senseair tSENSE Disp

Senseair tSENSE Disp Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info