759178
13
Zoom out
Zoom in
Previous page
1/13
Next page
- 13 - 09/2020
Copyright © 2020, Fast ČR, a.s.
a) Acquainting one'sself with the device and its activity.
b) Electrical disconnection of the system.
c) Prior to starting the procedure, ensure that:
if required, mechanical device for handling the cylinder with refrigerant is available;
all personal protective devices are available and used correctly;
the collection process is constantly under the supervision of acompetent person;
the collection device and cylinders comply with respective norms.
d) Pump out the cooling system if possible.
e) If achieving vacuum is not possible, collection pipes are created to enable the
collection of refrigerant from various parts of the system.
f) Ensure that the cylinder is placed on the scale before the collection of refrigerant is
started.
g) The collection device is turned on and runs according to the manufacturer's
instructions.
h) Cylinders are not overfilled. (No more than 80% of liquid content capacity).
i) The maximum operating pressure of the cylinder is not exceeded, even temporarily.
j) When the cylinders are properly filled up and the procedure is complete, ensure that
the cylinders and devices are immediately removed from the installation location
and that all the separation valves on the device are closed.
k) The collected refrigerant must not be filled into adifferent cooling system until it is
cleaned and checked.
10. Marking with alabel
The appliance must be marked with a label indicating that it has been put out of
operation and is without refrigerant. The label must be dated and signed. It is ensured
that there are labels on the appliance indicating that it contains flammable refrigerant.
11. Collection
When the refrigerant is collected from the system, either due to servicing or when it is
put out of operation, it is recommended to adhere to proper practice and safely collect
all the refrigerant.
When the refrigerant is transferred into the cylinders, it is necessary to ensure that
appropriate cylinders for collecting refrigerant are used.
It is necessary to ensure that there is a sufficient number of cylinders available to
contain the complete contents of the system. All the cylinders that are to be used must
be intended for collecting refrigerant and be marked with alabel for this refrigerant
(i.e. special cylinders for collecting refrigerant). The cylinders must be complete with
asafety valve and associated closing valves in good working condition. The empty
collection cylinders are pumped empty and if possible cooled prior to collecting
refrigerant.
The collection device must be in good operating condition with a set of manuals
relating to the device, which are on hand and it must be suitable for collecting
flammable refrigerants. Apart from this, aset of calibrated scales in good operating
condition must also be available. Hoses must be complete with couplers without
seepage and in good condition. Prior to using the collection device, check that it is in
satisfactory operating condition, has been properly maintained and all the associated
electrical components are sealed to prevent ignition in the event of refrigerant being
released. If in any doubt, consult the manufacturer.
The collected refrigerant must be returned to the refrigerant supplier in the correct
collection cylinder and with arespectively arranged waste transport letter. Refrigerants
are not mixed in the collection units and especially not in the cylinders.
In the event that compressors or compressor oils are to be collected, ensure that they
are pumped out to an acceptable level in order to ensure that flammable refrigerant
does not remain in the lubricant. The pump discharge process must be performed
before the compressor is returned to the supplier. To speed up this process, only
electrically heated compressor elements may be used. When the oil is drained from
the system, it must be disposed of safely.
TECHNICAL SPECIFICATIONS
SDH 2020WH
Power supply 220 - 240 V~ 50 Hz
Dehumidification capacity 20 l / 24 h
Rated input power 440 W
Rated current 2.3 A
Energy factor EEV 2.3 l/kWh
Starting current 10.0 A
Fuse type and current value T3.15A
Condensate tank capacity 3 l
Refrigerant type and weight R290 / 75 g
GWP (global warming potential) 3
Equivalent CO20.000225 tonnes
Air flow volume 168/125/99 m3/h (high / medium / slow fan
speed)
Noise level 58/43/41 dB (A) (high / medium / slow fan
speed)
Dimensions 350 × 245 × 510 mm
Weight net / gross 15.1/16.2 kg
Operating temperature 5 - 32°C
Recommended room area 37 - 52 m2
The declared noise emission level of the appliance is 58dB(A), which represents alevel
Aof acoustic power with respect to areference acoustic power of 1pW.
We reserve the right to change text and technical specifications.
INSTRUCTIONS AND INFORMATION REGARDING THE
DISPOSAL OF USED PACKAGING MATERIALS
Dispose of used packaging material at site designated for waste in your municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC
EQUIPMENT
This symbol on products or original documents means that used
electric or electronic products must not be added to ordinary
municipal waste. For proper disposal, renewal and recycling hand over
these appliances to determined collection points. Alternatively, in
some European Union states or other European countries you may
return your appliances to the local retailer when buying an equivalent
new appliance.
Correct disposal of this product helps save valuable natural resources
and prevents potential negative effects on the environment and human health, which
could result from improper waste disposal. Ask your local authorities or collection
facility for more details.
In accordance with national regulations penalties may be imposed for the incorrect
disposal of this type of waste.
For business entities in European Union states
If you want to dispose of electric or electronic appliances, ask your retailer or supplier
for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this product,
request the necessary information about the correct disposal method from the local
council or from your retailer.
This product meets all the basic requirements of EU directives
related to it.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SDH 2020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SDH 2020 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info