758825
7
Zoom out
Zoom in
Previous page
1/12
Next page
Blender
SBL 3271SS / SBL 3272RD
EN
EN-7
2015 11/2015
BEFORE FIRST USE
1. Take the appliance and its accessories out of the packaging materials.
2. Thoroughly wash all parts intended for contact with food (inner cap A1, outer lid A2, blending
jar A3, gasket seal A4 and Aqa, blade assembly A5 and Aqs, attachment collar A6 and Aqd,
grinding jar A0), using warm water and a neutral kitchen detergent. Then rinse them with clean
water and dry thoroughly with a fine wiping cloth.
Attention:
When cleaning the blending and grinding blade assemblies A5 and Aqs take special care to
avoid injury. The blades A5 and Aqs are sharp.
ASSEMBLING AND DISASSEMBLING THE APPLIANCE
Before you start assembling or disassembling the appliance, check that the motor unit A7 is turned
off and disconnected from the power socket and that the rotating parts have come to a complete
stop.
1. Assembling and disassembling the blending jar
1.1 Place the gasket seal A4 on to the blade assembly A5. Make sure that the gasket seal A4 properly
adheres along the entire perimeter of the blade assembly A5.
1.2 Place the blade assembly A5 with the gasket seal A4 into the attachment collar A6. Then, from
underneath, place this assembly against the blending jar A3. Screw the collar A6 to the blending
jar A3 anticlockwise and tighten firmly.
1.3 Place the inner cap A1 into the opening in the lid A2 so that the tabs along the perimeter of
the cap A1 slide into the grooves in the lid A2. Turn the cap A1 clockwise to secure it in the lid
A2. When you have placed all the necessary ingredients into the blending jar A3, close it with
the assembled lid. The lid needs to be properly pushed down along the entire perimeter so that it
adheres well to the edge of the blending jar A3.
1.4 When disassembling the blending jar, proceed in the reverse sequence.
2. Assembling and disassembling the grinder
2.1 Turn the grinding jar A0 so that the opening faces upwards. Place the gasket seal Aqa on to
the blade assembly Aqs. Make sure that the gasket seal Aqa properly adheres along the entire
perimeter of the blade assembly Aqs.
2.2 Place the blade assembly Aqs with the gasket seal Aqa into the opening of the jar A0 so that
the blades point into the jar A0. Attach the blade unit Aqs to the jar A0 by screwing collar Aqd
clockwise. Turn the assembled grinder so that the collar Aqd is facing downwards.
Note:
Place food into the jar A0 before attaching it to the blade assembly Aqs.
Unless you are grinding coffee beans, use blade assembly A5 instead of blade assembly Aqs.
Further instructions regarding the selection of the correct type of blade assembly can be found
in chapter Quick guide to processing ingredients.
2.3 When disassembling the grinder, proceed in the reverse sequence.
3. Attaching the blending jar and grinder to the motor unit and their removal
3.1 Place the motor unit A7 on an even, dry surface, for example on a kitchen countertop. On to the
motor unit A7 place the blending jar or grinder assembly and turn it clockwise all the way so that
it is secured on the motor unit A7. When the blending jar or grinder assembly is correctly attached
to the motor unit A7, it is not possible to freely lift it off the motor unit A7.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SBL 3271 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SBL 3271 in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info