- 13 -
Copyright © 2019, Fast ČR, a.s.
TECHNICAL SPECIFICATIONS
SAC MT9020C / SAC MT9021C
Power supply................................................................................................................................................................................................................................................................................................220–240 V~ / 50 Hz
Cooling power ...........................................................................................................................................................................................................................................................................................................9 kBtu / hour
Power input ..........................................................................................................................................................................................................................................................................................................................1,000 W
Current consumption ..........................................................................................................................................................................................................................................................................................................4.35 A
EER cooling factor ........................................................................................................................................................................................................................................................................................................................2.6
Dehumidification capacity ............................................................................................................................................................................................................................................................................................1 l / hour
Capacity of the built-in condensate tank ..........................................................................................................................................................................................................................................................................0.4 l
Refrigerant type and weight ...................................................................................................................................................................................................................................................................................R290/205 g
Air flow volume ................................................................................................................................................................................................................................................................................................................ 290 m
3
/h
Noise level ..............................................................................................................................................................................................................................................................................................65 dB (A) (high setting)
Maximum permitted value of excess operating pressure:
Suction / exhaust part of the cooling circuit .................................................................................................................................................................................................................................................... 1.2/2.3 MPa
Dimensions of the portable air conditioner (w× d × h)............................................................................................................................................................................................................. 440 × 325 × 695 mm
Weight .............................................................................................................................................................................................................................................................................................................................. 29 kg (net)
Operating temperature (cooling) ...............................................................................................................................................................................................................................................................................18–32 °C
Recommended room area ...........................................................................................................................................................................................................................................................................................20–31 m
2
SAC MT1220C
Power supply................................................................................................................................................................................................................................................................................................220–240 V~ / 50 Hz
Cooling power ..............................................................................................................................................................................................................................................................................................max. 12 kBtu / hour
Power input ..........................................................................................................................................................................................................................................................................................................................1,170 W
Current consumption .............................................................................................................................................................................................................................................................................................................5.2 A
EER cooling factor ........................................................................................................................................................................................................................................................................................................................2.6
Dehumidification capacity ........................................................................................................................................................................................................................................................................................ 1.5 l / hour
Capacity of the built-in condensate tank ..........................................................................................................................................................................................................................................................................0.4 l
Refrigerant type and weight ...................................................................................................................................................................................................................................................................................R290/235 g
Air flow volume ...............................................................................................................................................................................................................................................................................................................280 m3/h
Noise level ..............................................................................................................................................................................................................................................................................................65 dB (A) (high setting)
Maximum permitted value of excess operating pressure: Suction / exhaust part of the cooling circuit ................................................................................................................................1.2 / 2.3 MPa
Dimensions of the portable air conditioner (w× d × h)............................................................................................................................................................................................................. 440 × 369 × 720 mm
Weight .............................................................................................................................................................................................................................................................................................................................. 31 kg (net)
Operating temperature (cooling) ...............................................................................................................................................................................................................................................................................18–32 °C
Recommended room area ..........................................................................................................................................................................................................................................................................................30–41 m2
SAC MT1224CH / SAC MT1225CH
Power supply................................................................................................................................................................................................................................................................................................220–240 V~ / 50 Hz
Cooling power ...............................................................................................................................................................................................................................................................................................max. 12 kBtu/ hour
Heating power ........................................................................................................................................................................................................................................................................................................10 kBtu / hour
Power input (cooling/heating) .................................................................................................................................................................................................................................................................. 1,230 W/ 1,035 W
Current consumption (cooling/heating) ...........................................................................................................................................................................................................................................................5.4 A/ 4.6 A
EER cooling factor ........................................................................................................................................................................................................................................................................................................................2.6
COP heating factor .......................................................................................................................................................................................................................................................................................................................2.8
Dehumidification capacity ........................................................................................................................................................................................................................................................................................ 1.5 l / hour
Capacity of the built-in condensate tank ..........................................................................................................................................................................................................................................................................0.4 l
Refrigerant type and weight ...................................................................................................................................................................................................................................................................................R290/260 g
Air flow volume ................................................................................................................................................................................................................................................................................................................ 280 m
3
/h
Noise level ..............................................................................................................................................................................................................................................................................................65 dB (A) (high setting)
Maximum permitted value of excess operating pressure: Suction / exhaust part of the cooling circuit ................................................................................................................................1.2 / 2.3 MPa
Dimensions of the portable air conditioner (w× d × h)............................................................................................................................................................................................................. 440 × 369 × 720 mm
Weight .............................................................................................................................................................................................................................................................................................................................. 31 kg (net)
Operating temperature (cooling) ...............................................................................................................................................................................................................................................................................18–32 °C
Operating temperature (heating)...............................................................................................................................................................................................................................................................................10–25 °C
Recommended room area ...........................................................................................................................................................................................................................................................................................30–41 m
2
The declared noise emission level of the appliance is 65 dB(A), which represents alevel Aof sound power with respect to areference sound power of 1 pW.
Note:
The efficiency of the portable air conditioner may be reduced in the event that it is used outside the above described operating temperature range.
We reserve the right to change text and technical specifications.
INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS
Dispose of used packaging material at asite designated for waste in your municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT
This symbol on products or original documents means that used electric or electronic products must not be added to ordinary municipal waste. For proper disposal,
renewal and recycling hand over these appliances to determined collection points. Alternatively, in some European Union states or other European countries you
may return your appliances to the local retailer when buying an equivalent new appliance.
Correct disposal of this product helps save valuable natural resources and prevents potential negative effects on the environment and human health, which could
result from improper waste disposal. Ask your local authorities or collection facility for more details.
In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste.
For business entities in European Union states
If you want to dispose of electric or electronic appliances, ask your retailer or supplier for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this product, request the necessary information about the correct disposal method from the local council or
from your retailer.
This product meets all the basic requirements of EU directives related to it.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SAC MT1224CH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SAC MT1224CH in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info