7. Accessories
Mini Light Receptor (Sold separately)
Incident light receiving unit with a compact 12mm diameter
light receiving surface.
For measuring narrow areas used for photographing small
subjects or copy work.
Booster (Sold separately)
• For light measuring on camera ground glass, focusing
screens, SLR eyepieces, microscope eyepiece.
• When the Booster is used without any accessory
attachments, it can measure reflected light over
approximately a 60 degree angle of field.
Synchro cord (Sold separately)
This is a five-meter long cord with three plugs. An exposure meter, a camera, and a flash can all
be connected at the same time., This is convenient when measurements are made, because it is
not necessary to plug and unplug the synchro cord.
18% Gray Card (Sold separately)
18% gray card with cover (110mm x 102mm, 4 1/4" x 3 1/
2"), folds to 2 3/4" x 4 3/4", and fits in a shirt pocket.
Diopter Eye Correction Lenses (Sold separately)
Uses Nikon diopter lenses (-5Dp - +3Dp), for the Nikon
F801S/F-801. The eyepiece adapter DK-7 is required for
the diopters to attach and can be used as an eyecup for
eyeglass wearers.
-25-
8. Technical Data
• Type : Digital exposure meter for ambient and flash meter with built-in 1° to
4° nine lens elements, zoom lens
• Light receiving method : Incident light and reflected
Incident light : Convertible to flat diffuser (Lumisphere in down position)
Reflected light : 1° to 4° nine element Zoom
Metering distance 1m - infinity
• Light Receptors : 2-Silicon photo diodes (incident and reflected)
• Metering modes :
Ambient light : Aperture priority metering
Shutter priority metering
EV metering value
Flash : With synchro cord (cumulative, non-cumulative)
Without synchro cord (cumulative, non-cumulative)
• Measuring Range (ISO 100)
Ambient light : Incident light EV-2 to EV 19.9 (in 0.1 steps)
Reflected light EV 3 to EV 19.9 (in 0.1 steps)
Flash : Incident light f1.0 to f128 +0.9 stop (in 0.1 steps)
Reflected light f5.6 to f128 +0.9 stop (in 0.1 steps)
• Repeat Accuracy : +/- 0.1 EV or less
• Calibration Constant
Incident light metering : Lumisphere C = 340 Flat diffuser C = 250
Reflected light metering : K = 12.5
• Display Range
Film speed : ISO 3 to 8000 (in 1/3 steps)
Shutter Speeds
Ambient light : 30 minutes to 1/8000 seconds (single or half steps) also 1/200, 1/400
Cine speeds- 2, 3, 4, 6, 8, 12, 16, 18, 24, 25, 30, 32, 36, 40 ,48, 60,
64, 72, 96, 120, 128, 150, 200, 240, 256, 300, 360 frames per second
(at a 180 degree shutter angle)
Flash : 1 second to 1/1000 second (single or half steps) also 1/75, 1/80, 1/90,
1/100, 1/200, 1/400
Aperture : f/1.0 to f128 +0.9 stop (in 0.1 steps)
EV : EV -9.9 to EV 36.1 (in 0.1 steps)
Analog display : f/1.0 to f128 (in 0.5 steps)
• Other features
All-weather feature : JIS standard water resistance class 4, splash-proof type
Memory function : 3 readings in each incident mode (3 with Lumisphere Up and, 3 with
Lumisphere Down) and 3 in reflected spot mode
Multiple Flash function : Up to 9 flash readings
Average function
Brightness Difference function
Exposure Out of Range : Eu (underexposure) or Eo (overexposure) indication
Exposure index correction : +/- 9.9 EV (in 0.1 steps)
Battery Power Indicator display
Auto Power Off : approx. 20 minutes
-26-
15


Need help? Post your question in this forum.

Forumrules
1

Forum

sekonic-l-508

Reset search

  • How do i convert EV to LUX or foot candles to see the intensity of each light? I have the tables in the manual, but am unsure how to read them. Any help?? Submitted on 5-4-2022 at 06:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sekonic L-508 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sekonic L-508 in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sekonic L-508

Sekonic L-508 Quick start guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info