473076
24
Zoom out
Zoom in
Previous page
1/36
Next page
5
Measurement
3-2-2. Auto Reset Cordless Flash mode
Use this mode when a Synchro cord is too short, not available or use of a cord is
inconvenient.
Press the MODE button to select to the
Auto reset cordless flash mode.
Hold ISO button and press UP or DOWN
button to select the ISO sensitivity (See
page 11)
Press the UP button or the DOWN button
to set the desired shutter speed.
Select a shutter speed range that will synchronize with your camera and
flash system.
l
When the MEASURING button is pressed,
the mode mark will blink to indicate
that the meter is ready to measure. The
ready to measure mode will continue for
approximately 90 seconds.
Fire the flash to make a measurement.
If the 90 second period is exceeded and the blinking mark stops, press
the MEASURING button again to return to ready to measure status.
1)
2)
3)
4)
5)
M
O
D
E
MODE button
UP button
DOWN button
ISO button
Set shutter speed
21
1/10 step measurement
value (f stop)
Set shutter
speed
Measurement
value (f stop)
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sekonic L-308DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sekonic L-308DC in the language / languages: English as an attachment in your email.

The manual is 2,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sekonic L-308DC

Sekonic L-308DC User Manual - German - 36 pages

Sekonic L-308DC User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info