Immediately after the watch is swung to charge the KINETIC E.S.U., the second hand may not properly
indicate the power reserve. Please check again after 10 to 15 minutes have elapsed.
Precaution on see-through case-back models:
If your watch has a glass case back, do not expose the case back to strong light such as direct sunlight
or an incandescent light at close range, as this may temporarily increase the power consumption of the
watch circuit, thus reducing the power reserve in the KINETIC E.S.U. This condition, however, will be
corrected when the case back is turned away from the light.
TIME/CALENDAR SETTING
For Cal. 3M62 and Cal. 5M62, do not set the calendar between 9:00 p.m. and 1:00 a.m. For Cal. 5M63,
do not set the calendar between 9:00 p.m. and 3:00 a.m. Otherwise, it may not change properly. If it is
necessary to set the calendar during that time period, first change the time to any time outside it, set the
calendar and then reset the correct time.
To set the exact time, pull out the crown all the way when the second hand is at the 12 oclock position
and push it back in to the normal position in accordance with a time signal.
When setting the hour hand, check that AM/PM is correctly set. The watch is so designed that the calendar
changes once in 24 hours.
Turn the hands past the 12 oclock marker to determine whether the watch is set for the A.M. or P.M.
period. If the calendar changes, the time is set for the A.M. period. If the calendar does not change, the
time is set for the P.M. period.
When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn it back
to the exact minute.
When setting the time, make sure that the second hand is moving at one-second intervals.
It is necessary to adjust the date at the end of February and 30-day months. In this case, pull out the crown
to the first click and turn it until the desired date appears.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Seiko 5M63 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Seiko 5M63 in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Seiko 5M63

Seiko 5M63 User Manual - German - 1 pages

Seiko 5M63 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info